Performing Maintenance | 9
BeWa MFU-10P 4391553b en-us
89 / 124
2.
Remove the suction and pressure lances from the con-
tainer and empty them.
3.
Release the collet
(952)
on the quick coupling
(951)
by
hand in the anti-clockwise direction.
4.
Turn the quick coupling
(951)
by ≈ 90° anti-clockwise
and remove it.
ð
The Seal ring and the strainer behind it are now visible
and accessible.
O
Disassembly of the suction hose is complete.
For installation, proceed as follows:
5.
Attach the quick coupling
(951)
to the mating piece on
the filter unit
(700)
and rotate the quick coupling
(952)
by
≈ 90° in clockwise direction.
6.
NOTICE! If the collet is not or not adequately tight-
ened, the pump will draw air through the quick cou-
pling.
Pull the collet
(952)
at the quick coupling
(951)
by hand
in the clockwise direction.
7.
Put the filter unit into operation and check the filter unit
for leaks.
O
The assembly of the suction hose is complete.