Manual operation | 7
BeWa MFU-10P 4391553b en-us
71 / 124
2.
Connect the pressure hose to the oil tank/container and
fit the pressure hose in it and also secure it against fall-
ing out.
3.
Connect the filter unit to the voltage source.
4.
Switch the filter unit on at the main switch.
5.
Keep an eye on the display of the
ContaminationSensor
with the respectively current cleanliness class.
6.
If the display of the
ContaminationSensor
shows the re-
quired or a better cleanliness class, switch the filter unit
off.
7.
Release the pressure hose at the quick coupling, see
Removing/installing the quick coupling [
.
8.
Empty the contents of the pressure hose into the oil
tank/container.
9.
Empty the contents of the suction hose into the oil tank/
container.
10.
Secure the pressure hose at the quick coupling, see
moving/installing the quick coupling [
.
11.
Secure the cable and, if required, the hoses to the filter
unit, see
Transportation / Storage (< 6 months) [
.
O
Cleaning up to the required cleanliness class is com-
plete.