3.4.1 Achievable negative control values
The achievable
depends on the environmental condi-
tions.
Ambient conditions
CTM-EX 34xx
CTM-EF 36xx
Clean room
0.2 mg
0.3 mg
Laboratory
0.2 mg
0.3 mg
Separate sampling room
0.2 mg
0.3 mg
Plant/factory shed
0.2 mg
0.3 mg
Tab. 6: Achievable negative control values
≤ particle size
(metallic)
Requisite effort
Cleansing time af-
ter a brief shut-
down
(≤ 24 h)
Cleansing time af-
ter a longer shut-
down
(> 24 h)
100 µm
High
1 … 4 h
1 … 4 h
150 µm
Medium
1 … 2 h
1 … 2 h
200 µm
Low
0.5 h
0.5 h
Tab. 7: Requisite effort/cleansing time for negative control values