GENERAL SPECIFICATION
Instrument Type
:
Microflex LR Integral (MI)
Power Supply
: 2 wire 4-20mA loop (MI2) or 2,3,4 wired AC/DC (MI3)
Range
: Up to 60 metres
Blanking
: Variable from 0.3 metres (dependent on instrument type)
Process media
: Liquids or Solids
Analogue Output
: 4-20mA into 750 Ohm Ext. Supply.
400 Ohm Int. Supply.
Power Supply
: 12 - 30V DC
: 90 - 260V AC
Relays
: 2 Form C SPDT rated 0.5 amp at 240V AC (MI3)
Resolution
: 1mm up to 20 metre range
: 4mm from 20-60 metre range
Accuracy
: +/- 0.25% of maximum range
Operating temperature
: -40ºC to + 80ºC *
Ambient temperature
: Electronics -40ºC to + 80ºC *
Display
: 2 line 8 digit LCD
Enclosure
: Integral System IP67
Key Pad
: Integral 4 button
Mounting
: MI__10 2" NPT or BSPT
MI__20 4" Flanged ANSI, DIN or JIS
MI__40/60 10" Flanged ANSI, DIN or JIS
Weight
: MI_10 1.75Kg (Typical weight)
MI_20 3.5Kg (Typical weight including flange & cone)
MI_40 9.5Kg (Typical weight including flange & cone)
MI_60 13.5Kg (Typical weight including flange & cone)
Cable Entries
: M16 Cable Glands
Comms
: Modbus (MI3 option)
: Multi-drop capability (up to 32 units)
: Vision System II Software Package
: Hycontrol GSM Link (GSM/CDMA connectable)
*For ATEX models refer to ATEX Safety & Operating Instructions Manual.