background image

 

Side 

5

 af 

16

 

 

Technical Data 

 

 
 

 
 
 

 
 
 
 

 
 
 
 

 
 
 

 

Weight w/o hoses and lubricants 

29 kg 

 

Service weight 

31 kg

 

 

Dimension

 

Total length: 722 mm 

 

Total width: 460 mm 

 

Oil flow

 

Max. 30 l.p.m. 

 

Rotation speed

 

320 rpm 

 

Rotation direction  
(seen from the top) 

CCW

 

 

Rotation torque

 

45 Nm 

 

Striking energy

 

55 Joule 

 

Blow frequency

 

40 Hz 

 

Max. Drilling depth

 

3000 mm  

 

Max. Drilling hole size

 

Ø50 mm 

 

Working pressure 

150 bar

 

 

Max return pressure 

15 bar

 

 

Pressure relief valve 

on power source

 

Max. 172 bar  

 

Max. oil temperature

 

70° C 

 

Tool chuck size 

22x108 mm

 

 

Built in compressor air supply

 

8 m³/hr. 

 

Under water use

 

Please contact your HYCON dealer 

 

Vibration level 3 axis (ISO 20643) 

13.0 m/s²  

Uncertainty (K)

 

2.5 m/s²  

 

Sound power level L

WA

 guaranteed      

105 dB 

 

 

Содержание 19471

Страница 1: ...nce of your new tool we re commend you to study this operating manual carefully and pay special attention to the chapters about Safety and Service Precautions and Service Maintenance We hope you will...

Страница 2: ...This page is intentionally left blank...

Страница 3: ...Flow and Pressure 4 Starting Instructions 4 Technical Data 5 Performance Chart 6 Integrated Air Supply 6 Connection to Hydraulic Power Sources 7 Service and Maintenance 8 Oil Types 9 EC Declaration of...

Страница 4: ...ved hoses Contact your dealer if necessary The operator must pay extra attention and show caution when working in difficult working areas such as slopes and other dangerous nature of the ground Do not...

Страница 5: ...ck drill Always make sure that the rock drill labels and warning signs are legible Always use hoses couplings and spares as such recommend by HYCON A S Repairs may only be carried out by experienced p...

Страница 6: ...sure is correct and that the maximum allowed pressure is not exceeded On page 5 you will find a complete survey of the technical data and on page 7 there is a guide to connection to hydraulic power so...

Страница 7: ...triking energy 55 Joule Blow frequency 40 Hz Max Drilling depth 3000 mm Max Drilling hole size 50 mm Working pressure 150 bar Max return pressure 15 bar Pressure relief valve on power source Max 172 b...

Страница 8: ...sual first check the air filter and if that is ok please ask your HYCON dealer to check for worn out vanes The rock drill can be modified for external air Please contact your HYCON dealer 8 20 25 0 5...

Страница 9: ...upply is not too high the working pressure is not too high the return pressure is not too high the pressure relief valve is not set higher than 172 bar the internal diameter of the hoses is sufficient...

Страница 10: ...and require earlier replacing when drilling in areas with low ventilation in moist weather or when drilling in softer materials like concrete or limestone If drilling and the airflow stops stop drilli...

Страница 11: ...le oil which comply with the following values Ambient temperature range Below 10 C 50 F 10 30 C 50 68 F Above 30 C 68 F Recommended oil viscosity grade VG 32 VG 46 VG 68 Recommended oil cleanliness IS...

Страница 12: ...18328 service weight 32 kg is manufactured in conformity with the EC Directive 2006 42 EC HYCON A S Juelstrupparken 11 DK 9530 St vring Denmark Martin M ller Managing Director 01 08 2019 HYCON A S Jue...

Страница 13: ...applies to faults that can be related to construction and production errors Faults caused by incorrect operation incorrect handling lack of maintenance or the like will not be accepted as warranty Th...

Страница 14: ...Side 12 af 16 This page is intentionally left blank...

Страница 15: ...Side 13 af 16 This page is intentionally left blank...

Страница 16: ...Side 14 af 16...

Отзывы: