Side
8
af
16
Service and Maintenance
To ensure high performance reduce the risc of failure the following services are
required. Visit our webpage or youtube channel for instruction videos.
Daily (5 hours drilling)
Take out the air filter and tap it to release the dust, clean filter housing, install air
filter into cyclone housing.
Weekly (25 hours drilling)
Airfilter replacement required.
Two weeks (50 hours of drilling)
Air filter replacement required, clean filter housing, open compressor and clean rotor
and rotor housing, replace vanes.
Our service kit with HYCON part no. 9013500 covers the 25 hour and 50
hour services in one kit.
The air filter might be filled earlier and require earlier replacing when drilling in areas
with low ventilation, in moist weather or when drilling in softer materials like concrete
or limestone.
If drilling and the airflow stops,
stop drilling
and inspect drill rod. Low airflow might
cause the drill rod to clog with dust and in worst case result in the drill getting stuck.
MAINTENANCE
1)
Check hydraulic oil on a regular basis to ensure it is always clean. If the oil sticks
or changes the colour, replace it.
2)
Before starting, check if oil volume is sufficient as it decreases by connecting and
disconnecting the hoses.
3)
Grease gear box, one pump with a grease gun of an EP2 grade grease.
4)
The air filter protects the built-in compressor from sucking in dust. Take out the
the filter from the filter housing and clean it daily. The negligence of doing this
causes fast wear of the compressor vanes and housing.