 Safety Precautions

 

 
 

 

Read the rock drill and power source operating manuals prior to use. 

 

 

Only use the rock drill in accordance with the local working regulations on allowed 
working time 

 

 

Check the oil flow to the rock drill. The oil flow may not exceed 30 l.p.m.  

 

 

A fine jet of oil at pressure can penetrate the skin. It is therefore important never 
to use your fingers to check for oil leaks and never to hold your face close to su-
spected leaks – use a piece of cardboard instead. If oil has penetrated the skin, 

you should get medical treatment immediately.  

 

 

Never leave the rock drill when connected to the powerpack. 

 

 

Always use correct tool 

 

 

Make sure that the tool is firmly fastened 

 

 

Always use approved hoses. Contact your dealer, if necessary.  

 

 

The operator must pay extra attention and show caution when working in difficult 
working areas, such as slopes and other dangerous nature of the ground. Do not 

reach too far with the rock drill, but always maintain a good footing and keep your 

balance. 

 

 

The operator must be properly trained in using the rock drill or under supervision 

of a qualified instructor. 

 

 

The operator must always use protective goggles, earplugs, hard hat and shoes 

when operating the rock drill. 

 

 

Never wear loose clothing as it may get entangled in the moving parts of the rock 
drill. 

 

 

Inspection or cleaning of the rock drill, change of tool or disconnection of hoses 
may never be done while the rock drill is connected to the powerpack, as uninten-

tional activation can cause severe damage. 

  

 

Always connect hoses to the rock drill before starting the powerpack. Be sure that 
all couplings are tight. 

Содержание 19471

Страница 1: ...nce of your new tool we re commend you to study this operating manual carefully and pay special attention to the chapters about Safety and Service Precautions and Service Maintenance We hope you will...

Страница 2: ...This page is intentionally left blank...

Страница 3: ...Flow and Pressure 4 Starting Instructions 4 Technical Data 5 Performance Chart 6 Integrated Air Supply 6 Connection to Hydraulic Power Sources 7 Service and Maintenance 8 Oil Types 9 EC Declaration of...

Страница 4: ...ved hoses Contact your dealer if necessary The operator must pay extra attention and show caution when working in difficult working areas such as slopes and other dangerous nature of the ground Do not...

Страница 5: ...ck drill Always make sure that the rock drill labels and warning signs are legible Always use hoses couplings and spares as such recommend by HYCON A S Repairs may only be carried out by experienced p...

Страница 6: ...sure is correct and that the maximum allowed pressure is not exceeded On page 5 you will find a complete survey of the technical data and on page 7 there is a guide to connection to hydraulic power so...

Страница 7: ...triking energy 55 Joule Blow frequency 40 Hz Max Drilling depth 3000 mm Max Drilling hole size 50 mm Working pressure 150 bar Max return pressure 15 bar Pressure relief valve on power source Max 172 b...

Страница 8: ...sual first check the air filter and if that is ok please ask your HYCON dealer to check for worn out vanes The rock drill can be modified for external air Please contact your HYCON dealer 8 20 25 0 5...

Страница 9: ...upply is not too high the working pressure is not too high the return pressure is not too high the pressure relief valve is not set higher than 172 bar the internal diameter of the hoses is sufficient...

Страница 10: ...and require earlier replacing when drilling in areas with low ventilation in moist weather or when drilling in softer materials like concrete or limestone If drilling and the airflow stops stop drilli...

Страница 11: ...le oil which comply with the following values Ambient temperature range Below 10 C 50 F 10 30 C 50 68 F Above 30 C 68 F Recommended oil viscosity grade VG 32 VG 46 VG 68 Recommended oil cleanliness IS...

Страница 12: ...18328 service weight 32 kg is manufactured in conformity with the EC Directive 2006 42 EC HYCON A S Juelstrupparken 11 DK 9530 St vring Denmark Martin M ller Managing Director 01 08 2019 HYCON A S Jue...

Страница 13: ...applies to faults that can be related to construction and production errors Faults caused by incorrect operation incorrect handling lack of maintenance or the like will not be accepted as warranty Th...

Страница 14: ...Side 12 af 16 This page is intentionally left blank...

Страница 15: ...Side 13 af 16 This page is intentionally left blank...

Страница 16: ...Side 14 af 16...

Отзывы: