outdoors, provide a rain cover or a completely enclosed
shed to prevent corrosion.
If it is necessary to install the unit in a location that
will experience operating temperatures below 32°F, a
Hycomp crankcase heater must be installed. If the
booster is liquid cooled, suitable freeze protection must
be provided for both the coolant and the machine.
FOUNDATION
Installations require the booster be secured to a
concrete foundation pad. The foundation should
rest on solid bedrock, compacted earth, or gravel,
but not a combination of any. The pad should be
composed of 4,000 psi cured concrete reinforced with
ASTM A615 #4 billet steel re-bar cross laced on 16”
centers located 3” above the base. Refer to
Table 1
for amount of concrete required. SAE Gr. 5 “J” bolting
of appropriate length and size should be used in the
pad to provide baseplate mounting. Use of a template
to support and position the b/– 1/16” while
setting concrete is recommended. Securing bolting to
existing foundations with drilled holes and adhesives
is not to be used, unless expert advice is available.
RECEIPT OF BOOSTER
Immediately upon receipt of the booster, inspect the
unit and associated components for damage that may
have occurred during shipment.
Shipping damage
is not covered by Hycomp. Notify the shipping
company if there have been any damages.
Upon receipt of the booster, read the booster nameplate
to confirm the model ordered. Read the motor
nameplate to ensure that the electrical requirements do
not exceed existing conditions. Hycomp requires that
all personnel in charge of installation, maintenance,
or service of a Odyssey booster read this manual and
Operation Manual in their entirety.
LOCATION
Locate the booster in a dry, well ventilated and well lit
area that accommodates inspection and maintenance
access. Provide an unobstructed machine boundary of
at least 18” with adequate air flow and service space
around the booster. The area in front of the control
panel requires at least 36”. Check local electrical codes
to ensure proper distance. Rotating machinery should
always display appropriate restrictive warnings and
cautions to minimize risk of injury to personnel.
Rotating machinery can be a source of noise, which
may require abatement or personnel exposure limits.
Understand your service environment and prepare
accordingly. Noise from a typical Odyssey booster
may exceed 80 dBA @ 3ft.
Installation in locations exposed to ambient subfreezing
temperatures is not recommended. Exposure to direct
sunlight, rain, wind, dust, snow, moisture, and other
adverse environmental elements is not recommended
and will reduce service life and increase maintenance
requirements. If it is necessary to install the unit
BOOSTER INSTALLATION
GENERAL INFORMATION
NOTICE
: Odyssey boosters must only be installed in systems which have been designed by qualified personnel.
The system MUST conform to all applicable federal, state, local and national standards.
This manual is intended to assist qualified technical personnel in the installation of Hycomp Nitrogen Boosters.
NOTICE TO HYCOMP CUSTOMERS
Hycomp recommends you order service and replacement parts according to the model number and serial number
found on the nameplate of your booster. Do not order parts from the general descriptions in this manual. Ordering
directly from Hycomp or a registered vendor will minimize the possibility of receiving incorrect parts for your booster.
Booster
Model
Width
(in.)
Length
(in.)
Depth
(in.)
Weight
(lbs.)
DS015
27
52
8
975
DS026
27
52
8
975
DS033
27
52
14.5
1767
DS044
27
52
14.5
1767
DS060
31
56
16
2411
DS081
42
62
20
4521
DS087
31
56
16
2411
DS192
55
84
16
6417
DS133
55
84
16
6417
DS303
55
84
16
6417
Table 1: Foundation Requirements
Содержание DS015
Страница 1: ...Odyssey Easy Installation Guide...
Страница 10: ......