3
Disconnect the unit from power source before removing panels for
maintenance.
Before first use and after a long period of no use, the water tank and pipes
should be sanitised.
Do not install in environments where ambient temperatures are
< 10
0
C or > 38
0
C.
2. Installation
Plumbing
Before commencing installation, ensure the location is a flat level surface that
will allow for adequate airflow around all sides of the appliance.
Place the chiller in the final installation location and make a connection from the cold
water supply of the building to the chiller connection marked “WATER IN”.
It is strongly
recommended to fit a service valve on the branch for ease of future maintenance.
Cut to length the ¼” pipe provided to fit your installation. Take care to make a clean
straight cut and not to crush the ends of the pipe as this may cause the connection
to fail.
A brass adapter and plastic connector are provided to connect the ¼” pipe to 15mm
mains supply copper pipe. Two identical connectors are provided to connect the ¼”
pipe to the “WATER IN” inlet on the chiller and then to connect a new run of ¼” pipe
from the “WATER OUT” outlet of the chiller to the desired tap/ cold water dispenser.
The 2 black washers provided are for these 2 connectors and a locking collar is
provided for each of the 3 plastic connectors.
(Note: If a filter is specified, check the specific filter for guidance on any
installation and flushing procedures. Flushing of the filter should be performed
before connection to the chiller)
Commissioning
Open the cold-water outlet and then turn on the cold supply to the chiller, wait until a
smooth flow of water is dispensed to ensure any air is purged from the appliance
before closing the tap and checking all water connections for leaks.