5. Specifications

IN44T

IN60T

Power supply

230V~ 50Hz

230V~ 50Hz

Dimensions 

H140 x W190 x D80mm

H140 x W190 x D80mm

Power 

4400W

6000W

Protection class

IPX4

IPX4

Rated current

19A

27A

Over heat protection 

80

0

C

80

0

C

temperature

Minimum operating 

2.0L/Min

2.0L/Min

flow rate 

Minimum operating 

0.1MPa

0.1MPa

pressure

Maximum rated pressure

0.75MPa

0.75MPa

Required water resistivity

≥1300 Ωcm

≥1300 Ωcm

Maximum incoming water

60

0

60

0

supply temperature

Water fittings

1/2” BSP

1/2” BSP

80mm

190mm

140mm

IN44T & IN60TNEW_Layout 1  02/06/2015  14:37  Page 10

Содержание RHO IN44T

Страница 1: ...Product Instruction Manual Rho IN44T IN60T Instantaneous inline water heater Version 3 2 Jan 2015 V15 6 3...

Страница 2: ...2...

Страница 3: ...ician in accordance with the latest edition of the IEE wiring regulations Only connect the appliance to a power supply that conforms to the specification stated on rating plate The appliance must be e...

Страница 4: ...e visibility of any leak that might arise This is particularly important when locating in a concealed area such as a cupboard The heater must be mounted horizontally with the inlet and outlet connecti...

Страница 5: ...o the desired mounting surface Using the key hole slots The back plate of the heater is detachable by the four screws located in each corner Once removed use the backplate as a template and ensuring a...

Страница 6: ...that a service valve be fitted close to the product on the cold feed this will aide future maintenance The inlet is the left hand pipe and the outlet the right when viewed from the front The supplied...

Страница 7: ...accordance with the latest edition of the IEE wiring regulations Electrical supply should be capable of isolation via a double poled switch The heater must be earthed Isolate electric and water supply...

Страница 8: ...check the display the temperature display will flash if the set temperature cannot be reached It may be possible to reduce the flow rate in order to achieve the set temperature but it must have a mini...

Страница 9: ...nce Never open the cover of the heater without first isolating the mains power supply To clean the heater cover only use a clean damp cloth do not use abrasive compounds Electrical and plumbing compon...

Страница 10: ...s IPX4 IPX4 Rated current 19A 27A Over heat protection 800C 800C temperature Minimum operating 2 0L Min 2 0L Min flow rate Minimum operating 0 1MPa 0 1MPa pressure Maximum rated pressure 0 75MPa 0 75M...

Страница 11: ...ter and is correct specification as per the rating label Minimum flow not met Ensure a flow of at least 2L min For technical faults that cannot be resolved using the trouble shooting table contact the...

Страница 12: ...king life this equipment must not be disposed of as household waste It must be taken to a local authority waste collection centre or to a dealer providing this service Disposing of electrical and elec...

Отзывы: