background image

Pan Inverse

To select

Pan Inverse

, press the

ENTER

button to show the

PAN INVERSE

on the

display. Use the

DOWN

/

UP

button to select the

Inverse

(pan inversion) or

Normal

(normal) mode. Once the mode has been selected, press the

ENTER

button to

setup, to go back to the functions without any change press the

LEFT

button

again.

Tilt Inverse

To select

Tilt Inverse

, press the

ENTER

button to show the

TILT INVERSE

on the

display. Use the

DOWN

/

UP

button to select the

Inverse

(tilt inversion) or

Normal

(normal) mode. Once the mode has been selected, press the

ENTER

button to

setup, to go back to the functions without any change press the

LEFT

button

again.

Lamp Set (Power on/Delay/ Manual)
Lamp Power On /Delay/Manual

To select

Power On

, press the

ENTER

button to show the

POWER ON

on the

display. (Lamp on when power on) Press

UP

or

DOWN

button to show the

Delay

on the display.(Lamp on when the unit do resetting finish) Displayed the

Manual

.(Lamp on/off controlled by manual )

Содержание HMH 230

Страница 1: ...HMH230 BEAM User Manual Please read the instruction carefully before use ...

Страница 2: ...a location with adequate ventilation at least 50cm from adjacent surfaces Be sure that no ventilation slots are blocked otherwise the unit will be overheated Before operating ensure that the voltage and frequency of power supply matches the power requirements of the unit It s important to ground the yellow green conductor to earth in order to avoid electric shock Maximum ambient temperature TA 40 ...

Страница 3: ...may reach up to 85 Don t touch the housing bare handed during its operation and allow about 15 minutes for cooling the unit down before replacing bulb or maintenance as it could be very hot Avoid any inflammable liquids water or metal objects entering the unit Once it happens cut off the mains power immediately ...

Страница 4: ...nit as there are no user serviceable parts inside Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center if needed Disconnect the mains power if the fixture is has not been used for a long time Do use the original packing materials before transporting it once again To preve...

Страница 5: ...ter slave Sound active TFT display easy to control One gobo wheel 17 gobos Open One color wheel 13 colors Open Smooth 0 100 dimming and variable strobe speeds Voltage AC 100 240V 50 60Hz Power Consumption 330W LED OSRAM 230W Beam Angle 3 Weight 16 7Kgs Dimension 465 x 445 x 510mm ...

Страница 6: ...the selected function 4 How To Set The Unit LEFT Return to the top level and adjust the field RIGHT Adjust the field ENTER To confirm the selected functions UP To go backward in the selected functions DOWN To go forward in the selected functions DMX On DMX input present SOUND Flashing Sound activation ...

Страница 7: ...4 1 Main Function ...

Страница 8: ...p to go back to the functions without any change press the LEFT button again Run Mode To select Run Mode press the ENTER button to show the RUN MODE on the display Use the DOWN UP button to select the DMX or Auto or Sound or Master ON OFF or Lamp ON OFF or Channel 15CH 18CH Mode Once the mode has been selected press the ENTER button to setup to go back to the functions without any change press the...

Страница 9: ...Sound Mode Master ON OFF Lamp ON OFF Manual control the lamp ON or OFF Channel Mode 15CH 18CH Choose 15channels or 18 channels ...

Страница 10: ...y Screen Brand Means show the Hybrid on the panel when never operation Display Screen ON Means show the DMX address on the panel when never operation Display Screen OFF Blackout the panel when never operation ...

Страница 11: ...Test Mode For testing all function by manual Setup Mode ...

Страница 12: ...on to show the TILT INVERSE on the display Use the DOWN UP button to select the Inverse tilt inversion or Normal normal mode Once the mode has been selected press the ENTER button to setup to go back to the functions without any change press the LEFT button again Lamp Set Power on Delay Manual Lamp Power On Delay Manual To select Power On press the ENTER button to show the POWER ON on the display ...

Страница 13: ...s of the lamp Total Time the display will show the number of working hours of the unit DMX Clr Professional person make all channels of the unit will return to their standard position SysRst all channels of the unit will return to their standard position 5 Control By Universal DMX Controller 5 1 Connection ...

Страница 14: ...ed joints or corroded connectors can easily distort the signal and shut down the system 3 The DMX output and input connectors are pass through to maintain the DMX circuit when one of the units power is disconnected 4 Each lighting unit needs to have a DMX address to receive the data by the controller The address number is between 0 511 usually 0 1 are equal to 1 5 The end of the DMX 512 system sho...

Страница 15: ...ck to the last menu or let the unit idle one minute to exit menu mode Please refer to the following diagram to address your DMX512 channel for the first 4 units Channel mode Unit 1 Address Unit 2 Address Unit 3 Address Unit 4 Address 15 channels 1 1 6 3 1 4 6 18 channels 1 1 9 3 7 5 5 5 3 DMX 512 Configuration 15 Channels Mode Channel Function DMX Value 1 Pan 0 255 0 540 degree 2 Pan Fine 0 255 16...

Страница 16: ...lor 11 49 52 Color 12 53 56 Color 13 57 60 Color 14 61 127 Half color 128 189 Clockwise Rainbow rotation from slow to fast 190 193 Stop 194 255 Anti clockwise Rainbow rotation from slow to fast 9 Gobo 0 3 Open 4 6 Gobo 1 7 9 Gobo 2 10 12 Gobo 3 13 15 Gobo 4 16 18 Gobo 5 19 21 Gobo 6 22 24 Gobo 7 25 27 Gobo 8 28 30 Gobo 9 31 33 Gobo 10 34 36 Gobo 11 37 39 Gobo 12 40 42 Gobo 13 43 45 Gobo 14 46 48 G...

Страница 17: ...t 112 115 Gobo 14 shaking from slow to fast 116 119 Gobo 15 shaking from slow to fast 120 123 Gobo 16 shaking from slow to fast 124 127 Gobo 17 shaking from slow to fast 128 189 Clockwise Rainbow rotation from slow to fast 190 193 Stop 194 255 Anti Clockwise Rainbow rotation from slow to fast 10 Prism 0 4 None 5 255 Prism 11 Prism Rotation 0 127 Index rotation 128 189 Clockwise rotation from slow ...

Страница 18: ...e from slow to fast 168 203 Random slow strobe from slow to fast 204 239 Pulsation from slow to fast 240 247 Strobe from slow to fast 248 255 Open 9 Color 0 4 Open 5 8 Color 1 9 12 Color 2 13 16 Color 3 17 20 Color 4 21 24 Color 5 25 28 Color 6 29 32 Color 7 33 36 Color 8 37 40 Color 9 41 44 Color 10 45 48 Color 11 49 52 Color 12 53 56 Color 13 57 60 Color 14 61 127 Half color 128 189 Clockwise Ra...

Страница 19: ...shaking from slow to fast 88 91 Gobo 8 shaking from slow to fast 92 95 Gobo 9 shaking from slow to fast 96 99 Gobo 10 shaking from slow to fast 100 103 Gobo 11 shaking from slow to fast 104 107 Gobo 12 shaking from slow to fast 108 111 Gobo 13 shaking from slow to fast 112 115 Gobo 14 shaking from slow to fast 116 119 Gobo 15 shaking from slow to fast 120 123 Gobo 16 shaking from slow to fast 124 ...

Страница 20: ...ne 0 255 None 14 Focus 0 255 Focus from far to near 15 Frost 0 255 Frost function 16 P T marco 0 255 Pan Tilt marco 17 P T M speed 0 255 Speed from slow to fast 18 Function 0 129 None 130 139 Lamp on 140 199 None 200 209 Reset 210 229 None 230 239 Lamp off 240 255 None ...

Страница 21: ...heck the address settings and DMX polarity 3 If you have intermittent DMX signal problems check the pins on connectors or on PCB of the unit or the previous one 4 Try to use another DMX controller 5 Check to see if the DMX cables run near or run alongside high voltage cables that may cause damage or interference to DMX interface circuit C One of the channels is not working well 1 The stepper motor...

Страница 22: ...nce would cause malfunction of the fixture Cleaning The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth and use normal glas...

Отзывы: