Do not put obstacles around air-inlet or inside of air-outlet of the unit, such as window curtain 
etc. 

 

Always insert the filter securely, clean filter once every two weeks as required. 

CARE AND CLEANING 

FRONT PANEL AND CASE 

- Turn unit off and disconnect power supply. For cleaning, use water and a mild detergent. DO NOT use 
bleach and/or abrasives. Some commercial cleaners may damage the plastic parts. 

OUTDOOR COIL 

- Coil on outdoor side of unit should be checked regularly. Unit will need to be removed to inspect dirt 
build-up that will occur on the inside of the coil. 

If the coil is clogged with dirt and soot, it should be professionally cleaned. It is recommended to clean 
inside and outside of outdoor coils regularly. 

  NOTE: Never use a high-pressure spray on coil. 

 

UNIT DAMAGE HAZARD 

 

Failure to follow this caution may result in equipment damage or improper operation. 

 

Airflow restriction may cause damage to the unit. 

AIR FILTERS

  

IMPORTANT: TURN UNIT OFF BEFORE CLEANING 

 

 

Failure to follow this caution may result in equipment damage or improper operation. 

 

Do not operate unit without filters. If a filter becomes torn or damaged, it should be replaced 
immediately. 

 

Operating without filters or with damaged filters will allow dirt and dust to reach indoor coil and 
reduce cooling, heating, airflow and efficiency of the unit. 

- To maintain unit efficiency, it is required to clean filters once every two weeks. 

Clogged filters reduce cooling, heating and airflow. 

Содержание Advantage

Страница 1: ...Before using your air conditioner please read this manual carefully and keep it for future reference PACKAGED TERMINAL AIR CONDITIONER HEAT PUMP ...

Страница 2: ...S 3 IMPORTANT SAFETY INSTRUCTIONS 5 AIR CONDITIONER FEATURES 7 CONTROL PANEL OPERATION 9 DIP SWITCHES CONFIGURATIONS Optional 11 INSTALLATION 16 CARE AND CLEANING 20 TROUBLESHOOTING 22 OPTIONAL WIRED WIRELESS DIGITAL WALL STATS 24 ...

Страница 3: ...ey have been given supervision or instruction concerning use of the appliance by a person responsible for their safety applicable to all non European countries Children should be supervised to ensure that they do not play with the appliance If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid any hazard The applian...

Страница 4: ...rd close to heating appliances It may cause fire and electric shock Do not damage or use an unspecified power cord It may cause electric shock or fire Do not direct airflow at room occupants only It may cause electric shock or fire If the power cord is damaged it must be replaced by the manufacturer or an authorized service center or a similarly qualified person in order to avoid a hazard Always i...

Страница 5: ...amage due to falling of unit Do not place heavy object on the power cord and ensure that the cord is not compressed in any way There is danger of fire or electric shock Ventilate the room well when used together with a stove etc An oxygen shortage may occur Do not use for special purposes Do not use this air conditioner to preserve precision devices food pets plants and art objects It may cause de...

Страница 6: ...g is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician to properly install it Ensure the receptacle is accessible after...

Страница 7: ...d is now supplying electricity to the unit On some products this also indicated by a light on the plug head NOTES Do not use this device to turn the unit on or off Always make sure the RESET button is pushed in for proper operation The power supply must be replaced if it fails reset when either the TEST button is pushed or it cannot be reset A new one should be obtained from the manufacturer The p...

Страница 8: ...hen the evaporator temperature gets too low Automatic Quick Warm up for heat pump models only If the room temperature falls to 4 5 C 8 F below the set point temperature the reverse cycle heat is shut off and the electric strip heat is turned on for one cycle until the set heat is attained LED Indicators and Buttons The touch pad has buttons for MODE FAN POWER SETPOINT UP and SETPOINT DOWN It also ...

Страница 9: ...COOL The range of set temperature is 17 C 62 F 30 C 86 F Cooling begins automatically when the room temperature is above the set point and stops when the room temperature is 2 C 4 F below the set point But the compressor will run 5 minutes at least in COOL mode before stopping The fan runs in continuous mode HEAT The range of set temperature is 17 C 62 F 29 C 84 F For heat pump models the unit can...

Страница 10: ...ature Control code on some models LC Pads on the control panel is not available The unit can be set by using wire controller only LF Pads on the control panel and wire controller are not available The unit can be set by using FRONT DESK CONTROL only Error codes AS Room temperature sensor error ES Evaporator temperature sensor error CS Condenser temperature sensor error OS Outside temperature senso...

Страница 11: ...panel DIP SWITCHES CONFIGURATIONS Optional REMOVING THE FRONT PANEL Dip switches controls are located behind front panel through an opening below the control panel To access remove front panel See Fig 2 Dip switches are accessible without opening the control box See Fig 3 Unit must be powered OFF to effectively change their status DIP SWITCHES CONFIGURATIONS See Table 1 and Fig 4 for Dip Switches ...

Страница 12: ...eating Wall Thermostat Enable A wired wall thermostat can be connected to the unit In order to do so dip switch must be moved to the Wall Thermostat Enable Position before the wall thermostat will begin control Setpoint Temperature Limits Provides a restricted range of temperature control Heat and Cool Fan CON CYC Dip switches Allows the fan to operate in continuous or cycle ...

Страница 13: ...MPORTANT Only trained qualified personnel should access electrical panel on unit and install electrical accessories Please contact your local electrical contractor dealer or distributor for assistance Thermostat Wire Routing Thermostat wire is field supplied Recommended wire gauge is 18 to 20 gauge solid thermostat wire NOTE It is recommended that extra wires are run to the unit in case any of the...

Страница 14: ...struction of some types of wall stats you can consult with the sales agency or manufacturer for details Pull the dip switch DOWN OFF as shown below Insert the wire connector of the wall stat into the relevant terminal according to different shapes as shown below Installation instruction of PTAC other Wall Thermostat Remove the two screws as shown below and take the cover panel down ...

Страница 15: ... Failure to follow this caution may result in equipment damage or improper operation Improper wiring may damage unit electronics Common wire busing is not permitted Damage or erratic operation may result NOTE Use terminal 4 way for heat pump connection only ...

Страница 16: ... the unit type heat pump or Electric heat If it has only one electrical heater output connect the two terminals of HEAT 1 and HEAT 2 the unit can operate two electrical heaters only for the unit that has two electrical heaters Otherwise operate one electrical heater only FRONT DESK CONTROL The controller can handle a switch signal from FC L and FC N input called front desk control Input must be 24...

Страница 17: ...onditioner To avoid vibration and noise make sure the unit is installed securely and firmly When installing the sleeve make certain there is nothing within 20 inches of the back that would interfere with heat radiation and exhaust air flow See Fig 2 PREPARATION OF SLEEVE ASSEMBLY optional Refer to the installation instruction of sleeve assembly for details UNIT INSTALLATION Carefully remove shippi...

Страница 18: ...18 INSTALLATION CONTINUED UNIT INSTALLATION CONTINUED Rotate the vent control lever to either open or close the vent door See Fig 6 ...

Страница 19: ...set at OPEN some outdoor air will be drawn into room This will reduce heating or cooling efficiency Lift unit level and slide unit into wall sleeve until firmly against front of wall sleeve and secure with 4 screws and washers supplied in the SLEEVE ASSEMBLY through the unit flange holes See Fig 7 and Fig 8 ...

Страница 20: ...ofessionally cleaned It is recommended to clean inside and outside of outdoor coils regularly NOTE Never use a high pressure spray on coil UNIT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation Airflow restriction may cause damage to the unit AIR FILTERS IMPORTANT TURN UNIT OFF BEFORE CLEANING Failure to follow this caution may result in equipment da...

Страница 21: ...NT TURN UNIT OFF BEFORE CLEANING To open the vent door the removal of the unit from the wall sleeve is required Clean the vent filters twice a year or as required Make sure to remove the shipping screw from the vent door See Fig 5 Rotate the vent control lever to open the vent door See Fig 6 Remove four screws from the vent door filter See Fig 11 First pull out the vent door steel wire from the ho...

Страница 22: ...ROOM Unit air discharge section is blocked Temperature setting is not high or low enough Note Setpoint limits may not allow the unit to heat or cool the room to the temperature desired Check section on dipswitch settings Unit air filters are dirty Room is excessively hot or cold when unit is started Vent door left open Unit may be in a protection mode Compressor is in time delay Make sure that cur...

Страница 23: ... OR FROST FORMS ON INDOOR COIL Low outdoor temperature Dirty filters When outdoor temperature is approximately 55 F or below frost may form on the indoor coil when unit is in cooling mode Switch unit to FAN operation until ice or frost melts COMPRESSOR PROTECTION Power may have cycled so compressor is in a restart protection Random Compressor restart Whenever the unit is plugged in or power has be...

Страница 24: ...rainage could drip in an undesirable location an accessory drain kit should be installed and connected to drain system OPTIONAL WIRED WIRELESS DIGITAL WALL STATS AND EMS SYSTEMS DIP SWITCH 24V WIRED CONTROL Digital Wired Wireless Wall Stat Terminal ...

Страница 25: ...25 Hybrid Wired Thermostat Installation To install Hybrid wired thermostat plug it in directly to the unit as shown below Digital stat Wire Controller front desk Front desk 24 V controller ...

Страница 26: ...26 Controller for Hybrid Wired Stat Hook up wall stat connector with the digital stat controller encircle in RED 24V Controller for PRO1 wireless or other wired modules ...

Страница 27: ...27 Hook up wall stat connector to the unit as shown in the image It s recommended to affix wall stat wire with sticker so as to avoid any damage related to assembling the unit ...

Страница 28: ...NFIGURATION Steps to follow 1 Power OFF the unit 2 Turn OFF all the dip switches by push them DOWN 3 Turn ON S3 which is 2 OR SECOND switch on the second block from right by pushing it UP Also encircle in RED below 4 Detach the controller cover ...

Страница 29: ...29 5 Connect the wireless or wired module with controller as per the table below ...

Страница 30: ...30 6 Jump the connection between Heat 1 Heat 2 as shown below 7 After connecting the stat with unit apply double sided sticker at the back of the wireless module ...

Страница 31: ... module to unit as depicted below 9 Set the thermostat to OFF 10 Set CO to b on thermostat as per the procedure below a Press hold on thermostat until it displays CA 1 then press them again to get either CO b or CO 0 ...

Страница 32: ...yed then press to change it to CO b ii If CO b is displayed then wait for the thermostat until it returns to temperature screen 11 Replace the cover and assemble the unit 12 Turn ON the unit and allow 3 minutes response time ...

Отзывы: