SECTION 5 | WIRING DIAGRAMS
5.2 | UPPER CONTROL WIRING DIAGRAM
Part No WD-144-21-0075-50
2
1
NO
ENABLE
2
1 NC
E-STOP
2
1 NO
ELEV.
2
1 NO
LWR
NO
NC
LIMIT
SWITCH
4
3
2
1
BATTERY GAUGE
BATT+
BATT-
-
+
BATT +
BATT -
PUMP SOL./UP COIL
(OPTIONAL ALL-MOTION ALARM)
BATT -
RED
BRN
WHT
BLK
GRN
NC
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
B-SIZE
ORIGINALLY DRAWN BY:
Custom Equipment, Inc.
Richfield, WI 53076
Phone: (262)644-1300
DATE:
WD,UPR CTL HB-P827/1027
SCALE:1:1
DO NOT SCALE DRAWING
THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY TO CUSTOM, EQUIPMENT AND IS LOANED IN EXPECTATION THAT IT WILL BE KEPT CONFIDENTIAL AND USED ONLY FOR THE PURPOSE FOR WHICH IT IS LOANED.
SPEC/MATL: Wiring Diagram
DRAWING #: WD-144-21-075-50
REV
DESCRIPTION OF CHANGE
DATE REV BY
B
5 COND. MAIN CBL WAS 4 COND.
08/01/2017
GLH
ECO #
2017-3153B
SHEET 1 OF 1
WEIGHT: APPROX. 0.00 LB.
B
MAINTENANCE & TROUBLESHOOTING
HB-P827/HB-P1027
SUPO-722
REV B
BY CUSTOM EQUIPMENT LLC
22