![HWH 225 Series Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/hwh/225-series/225-series_operators-manual_2190582027.webp)
MP85.283J
13FEB04
CLEAR OF ROOM WHEN OPERATING.
UNDERSTAND OPERATOR’S MANUAL BEFORE
USING. KEEP PEOPLE AND OBSTRUCTIONS
HYDRAULIC ROOM EXTENSION
W
CORPORATION
OFF
CAUTION!
ON
H
RETRACT
EXTEND
H
R
ROOM CONTROL PANEL
ELECTRICAL CONNECTION DIAGRAM
ROOM EXTENSION CONTROL
WHITE
BLACK
5000
5100
6810
6230
8601
PUMP
SW
BATT
GND
RET
EXT
KEY
SWITCH
ROOM
CONTROL
SWITCH
REVERSE SIDE
ROOM CONTROL PANEL
NOTE: THERE IS A SEPARATE ROOM
CONTROL PANEL AND HARNESS WITH
PUMP RELAY AND SOLENOID VALVE
CONNECTIONS FOR EACH ROOM
EXTENSION.
6810
15 AMP
FUSE
8601
15
PUMP RELAY
PANEL ON
SYSTEM
LEVELING
BATTERY
FROM
(6820) +12
MOTOR
TO PUMP
WITH
SYSTEM PANEL
PUMP CONTROL
(8600) SW GRND
FROM LEVELING
VALVE CONNECTIONS
ROOM EXTENSION MANIFOLD FOR SOLENOID
SEE ELECTRICAL CONNECTION DIAGRAM
5000
5100
6245
6245
WIRE FUNCTIONS
5000 - SW12 FOR CYLINDER EXTEND SOLENOID VALVE
5100 - SW12 FOR CYLINDER RETRACT SOLENOID VALVE
6230 - GROUND FOR ROOM CONTROL PANEL
6245 - GROUND FOR ROOM SOLENOID VALVES
6810 - SW12 FROM PUMP RELAY
8601 - SWITCHED GROUND - PUMP RELAY CONTROL
GROUND
STUD ON
PUMP
TO HWH
6230
BLACK
WHITE
Содержание 225 Series