GROUND
BATTERY
PUMP RELAY HARNESS
FROM VALVE
PUMP MUST BE MOUNTED SOLIDLY TO FRAME. SOME PUMPS HAVE
A GROUND CABLE THAT IS TO BE ATTACHED TO THE GROUND STUD.
WIRES ARE LABELED, RELAY
WIRES CANNOT BE REVERSED
ELECTRICAL CONNECTION DIAGRAM
BI-AXIS VALVE WITH ROOM EXTENSION
PUMP RELAY
MP85.1725
22JAN03
* FUSE
* FUSE MAY BE REQUIRED - CHECK APPLICABLE CODE
-
SEE GROUNDING
ELECTRICAL
CONNECTION
DIAGRAM
(WHITE) 6230
SYSTEM
HARNESS
SEE ROOM EXTENSION
MANIFOLD WIRING
DIAGRAM
(BLUE) 6820
(BLUE) 6820
FUSE 10 AMP
ROOM EXTENSION
HARNESS
(WHITE) -
LEVELING
PUMP RELAY AND PANEL WIRING
FUSE
15 AMP
(RED) 6810
(RED) 6810
(GRAY) 8601
8600
6231
6245
NOTE: THE (4) DIGIT WIRE NUMBER
SUPERSEDES ANY AND ALL WIRE
COLORS.
(WHITE) 6230
PANEL CONNECTION DIAGRAM
1 - GROUND - (WHITE) 6230
2 - PUMP - (BLUE) 6820
3 - (-)WARN. LIGHT - (BROWN) 7699
4 - (+)WARN. LIGHT - (PURPLE)6121*
5 - LEFT REAR - (GREEN) 4000
6 - LEFT FRONT - (ORANGE) 1000
7 - RIGHT FRONT - (GRAY) 2000
8 - RIGHT REAR - (BLACK) 3000
9 - NOT USED
* NOT USED WITH ALL SYSTEMS
9-PIN MTA HARNESS
REAR - ORANGE (RED)
FRONT - BLACK
LEFT SIDE - YELLOW
RIGHT SIDE - GREEN
GROUND - WHITE
5-PIN MTA
NOTE: THE (4) DIGIT WIRE
NUMBER SUPERSEDES ANY
AND ALL WIRE COLORS.
FUSED +12 ACC.
POWER 15 AMP MAX.
(RED) 6120
SENSING UNIT
PARK/BRAKE
4-PIN MTA
NOTE: THIS RED WIRE
WITH SINGLE PACKARD
IS ONLY USED WITH
ELECTRONIC
SENSING UNIT
(BLUE)
9000
PIN 1
Содержание 200 series
Страница 24: ......