In general
Congratulations on your new HWAM insert. We are pleased that you have chosen a HWAM insert and
confident that it will give you much pleasure. To ensure optimum operation and safety, we recommend
that the installation should be carried out by an authorised HWAM retailer or a fitter recommended by
the retailer. For an overview of HWAM retailer, visit www.hwam.com under “Retailer locations”.
Safety
The installation of your HWAM insert must always comply with all European, national and local building
regulations. The installation must be carried out in accordance with the instructions in the installation
and user manuals and subsequently registered with the local authorities. Upon installation, the chimney
sweep must approve the installation before you can start using the insert. All HWAM insert packaging
material must be handled in accordance with local waste management regulations.
Room requirements
Always ensure a supply of fresh combustion air to the room where the insert is to be installed. The insert
uses approx. 9-23 m
3
of air per hour (depending on the setting of the air control lever). A window that
can be opened or an adjustable air valve will be sufficient. It must not be possible to block the adjustable
air valve/grate. In newly built/airtight dwellings, we recommend that a fresh air system should be installed
for the direct supply of external air to the combustion. This fresh-air system may be bought separately.
Before installing the insert, make sure that the floor can carry the insert, the chimney and any other
parts required for the installation.
Please be aware that not all glass parts are heat-resistant. For this reason, a glass wall should sometimes
be treated as a combustible wall, in which case we ask you to contact your local chimney sweep or glass
producer to hear at what distance the insert should be kept from glass.
Technical measures and data
Test results from nominal test EN 13240
Nominal heating effect
7,0 kW
Flue gas temperature EN 13240 measurement point
275ºC
Flue gas temperature measured in the outlet socket
296ºC
Exhaust gas flow
5,51 g/s
Efficiency
80,7%
Annual efficiency (EcoDesign)
70,7 %
PM
26 mg/m
3
OGC
76 mg/m
3
NOx
121 mg/m
3
CO at 13% O
2
1125 mg/m
3
CO at 13% O
2
0,09 %
Energy efficiency index
107
Energy efficiency class
A+
Test result based on NS 3058
Particle emissions
3,31 g/kg
The declaration of performance (DoP) can be downloaded from our website, www.hwam.com.
Содержание I30/55
Страница 1: ...I30 55 01 11 2020 97 9637 www hwam com AUTOPILOT User s Manual EN ...
Страница 3: ...Page 3 of 20 pages 1 1 1 A1 A2 A3 7 8 5 6 5 4 3 2 a 39 1 cm b 40 4 cm 1 2 ...
Страница 4: ...Page 4 of 20 pages D C 3 2 1 B 1 1 1 6 5 4 ...
Страница 5: ...Page 5 of 20 pages E F G 1 1 1 2 2 H ...
Страница 6: ...Page 6 of 20 pages ...
Страница 20: ...www hwam com ...