Page 18 of 20 pages
o
peratIonal
problems
Blackened glass
• The wood is too damp. Only use wood stored for at least 12 months under cover and with a
moisture level not exceeding 12-18% RH.
• Faulty seal in door. Fit new seal.
Smoke in the room when opening door
• The grate in the chimney may be closed. Open the grate.
• Insufficient chimney draft. See section on chimney or contact chimney sweep.
• Soot door leaking or dislodged. Replace or refit.
• Never open the door when there are still flames on the wood.
Uncontrollable combustion
• Faulty seal in door or ash pan. Fit new seal.
• If there is an excessive chimney draft, it may be necessary to set the air control knob to its minimum position.
Also do this all when the stove is not in use.
• If the steel plates in the combustion chamber develop scales or become deformed, this is due to
excessive heat. Stop using the stove and contact the retailer.
At interruptions that you cannot yourself rectify, you should contact the retailer.
d
eclaratIon
oF
p
erFormance
The DoP can be downloaded from our website via the following link:
www.hwam.com/dop/i30-55
Содержание I30/55
Страница 1: ...I30 55 01 11 2020 97 9637 www hwam com AUTOPILOT User s Manual EN ...
Страница 3: ...Page 3 of 20 pages 1 1 1 A1 A2 A3 7 8 5 6 5 4 3 2 a 39 1 cm b 40 4 cm 1 2 ...
Страница 4: ...Page 4 of 20 pages D C 3 2 1 B 1 1 1 6 5 4 ...
Страница 5: ...Page 5 of 20 pages E F G 1 1 1 2 2 H ...
Страница 6: ...Page 6 of 20 pages ...
Страница 20: ...www hwam com ...