IP Relay – 2x relay + RS-232 / Ethernet converter
HW group
June 2006
www.HW-group.com
Page 6 / 28
Technical parameters
Ethernet port
+ Interface
RJ45 (10BASE-T / 100BASE-Tx)
+ Compatibility
Ethernet: Version 2.0/IEEE 802.3
+ Supported protocols
IP: ARP, TCP/IP, NVT, RFC2217, UDP/IP
+ Network modes
TCP/IP server, TCP/IP client/server, UDP/IP
+ Communication security
128-bit TEA cipher, predefined range of IP addresses
Serial port 1 DB9F
+ Data bits
7, 8 or 9
+ Stop bits
1 or 2
+ Parity
None / Odd / Even / Mark / Space
+ RS-232 interface
RxD,TxD,RTS,CTS,GND
+ Communication speed
Adjustable in the range of 50..115200 Bd
Channel configuration possibilities
PO
(
Power On
)
When device switched on, the external supply voltage is lead out over (A = +,
B = GND)
Max current 100mA (50mA/Channel).
PF
(
Power Off)
When device switched on, the pins A and B are unpowered (A = +, B = GND)
Max current 100mA (50mA/Channel).
NO
(
normally open)
Switching contact remains open when the power supply is turned on.
NC
(
normally close
)
Break contact remains closed when the power supply is turned on.
+ Max. load of the contacts
max. 50V / 1A DC
Environment parameters
+ Temperature
Operation :
-5 to +50 °C ,
Storage :
-5 to +75 °C
+ Relative humidity (non-condensing)
5 to 95 %
LED diodes
+ POWER
(green)
GREEN – power supply turned on
+ LINK & Activity
(green)
GREEN - Ethernet connection
+ LED3 - D0
(yellow)
Controlled via NVT as a D0 output
In the combination with HW VSP or IP Relay Control, tied with Channel 1
+ LED4 - D1 (
red)
Controlled via NVT as a D1 output
+ LED4 - D7
(green)
Controlled via NVT as a D7 output
In the combination with HW VSP or IP Relay Control, tied with Channel 2
DIP switches
+ DIP1 - RS-232 Setup
ON = RS-232 Setup mode (9600 8N1)
OFF = Ethernet mode
+ DIP2 - Remote Input
ON = D4 remote input = Log. 1
OFF = D4 remote input = Log. 0
+ DIP3, DIP4
Not used
Other parameters
+ Supply voltage
12-15 V/ 150 mA DC- coaxial connector (barrel), GND on the shield
+ Dimensions
25 x 82 x 90 [mm] (H x W x D )
+ Mounting method
Separate box, “L” plates or DIN molding attachment
+ Weight
450 g