Dear Client

Thank you for Purchasing our

HTZZ-5A Transformer DC

Winding Resistance Tester

. Please read the manual in detail prior

to first use, which will help you use the equipment skillfully.

Our aim is to improve and perfect the

company's products continually, so there may be

slight differences between your purchase equipment

and its instruction manual. You can find the changes

in the appendix. Sorry for the inconvenience. If you have further

questions, welcome to contact with our service department.

The input/output terminals and the test column

may bring voltage, when you plug/draw the test wire or

power outlet, they will cause electric spark. PLEASE

CAUTION RISK OF ELECTRICAL SHOCK!

Company Address:

T4

No. 41, High-tech 2 Road

East Lake High-tech Development Zone

Wuhan

Sales Hotline: 86-27- 87457960

After Service Hotline

:

86-27- 87459656

Fax: 86-27- 87803129

E-mail: [email protected]

Website: www.hvtest.cc

Содержание HTZZ-5A

Страница 1: ...anual You can find the changes in the appendix Sorry for the inconvenience If you have further questions welcome to contact with our service department The input output terminals and the test column m...

Страница 2: ...and prevent the product or other relevant subassembly to damage In order to avoid possible danger this product can only be used within the prescribed scope Only qualified technician can carry out main...

Страница 3: ...d the instruction manual to acquire information about the ratings Do Not Operate without Covers Do not operate this product when covers or panels removed Use Proper Fuse Only use the fuse with type an...

Страница 4: ...Security Terms Warning indicates that death or severe personal injury may result if proper precautions are not taken Caution indicates that property damage may result if proper precautions are not tak...

Страница 5: ...5 Contents I Summarizes 6 II Technical indicators 7 III Method of use 8 IV Failure analysis and troubleshooting 10 V Matters needing attention 10...

Страница 6: ...ire and wire windings Check the location of each switch contact is good Check the winding or lead wire is broken at Correctness check parallel branches the existence of winding consists of several par...

Страница 7: ...n Small size light weight easy to carry Measurement and analysis of the utility model is suitable for all kinds of inductive low resistance power transformer transformer winding etc II Technical indic...

Страница 8: ...button C1 3 test button P1 4 test end button P2 5 test end button C2 6 printer 7 operation keys 8 power switch 9 AC220V power supply jack 10 ground terminal button III Method of use 3 1 will be connec...

Страница 9: ...he tested equipment DC resistance value then press the confirm key values will be saved and lock When the screen long time display out of range press the back button to return to the previous menu sel...

Страница 10: ...not installed or Circuit breaker Re install the insurance tube or replace the insurance tube No current output 1 to open inspection equipment Inspection equipment Trouble shooting 2 test circuit has...

Страница 11: ...do not touch any metal parts 5 4 initial measurement the instrument display numerical jitter or short time display beyond the range is due to the test equipment is not fully charged waiting to read af...