Operating Principles

 

The purpose of the HVS is to ventilate your home with introduced air which is fresher and drier 
than  the  air  inside  your  home  in  a  controlled  manner.  Air  from  the  roof  space  replaces  stale 
humid air which causes condensation, which can lead to mould and damp problems, or at least to 
reduce them to an acceptable level. 
 
The  diagram  (below)  shows  how  the  system  works.  Air  is  transferred  from  the  roof  space 
because  it  is  always  warmer  than  the  outside  air.    During the  night, the  roof  space  cools  down 
(but  usually  not  as  cold  as  outside)  and  air  flow  into  the  home  is  reduced,  but 

NOT

  stopped 

completely, to control condensation. 
 
A  small  continuous  supply  of  fresh  air  into  the  home  is  required  to  banish  condensation  during 
winter.  The ventilation  air supply positively pressurises the home causing stale air  to be gently 
forced out through cracks under doors, floor boards etc. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
This  method  of  positive  pressure  ventilation  (PPV)  is  the  most  cost  effective  way  to  reduce 
moisture build up in the home. 
 
Outside  doors  and  windows  could  be  left  open,  which  will  allow  in  the  necessary  fresh  air, 
however there are a number of draw backs with this approach such as security, inability to control 
the flow rate (too much or not enough) and the increased heating cost that would be required to 
over come these cold draughts. 
 
Heat  Pumps  (reverse  cycle  air-conditioners)  do  not  de-humidify  in  heating  mode  and  are  only 
effective in summer cooling mode.  Room de-humidifier units are very expensive to run and like 
moisture  crystals  have  little  effect  on  moisture.  None  of  them  provide  the  necessary  fresh  air 
ventilation that your home requires. 

 

 

Содержание "Warm N Dry" HVS1

Страница 1: ...What Is Condensation Control 3 What Is Heat Recovery Ventilation 3 Operating Principles 4 OPERATING GUIDELINES 5 General 5 Control Panel 6 Summer Months 7 Factory Default Settings 7 Other Settings 7...

Страница 2: ...logy Home Ventilation Solutions now manufactures its own systems built in Tasmania for Tasmanian conditions and sold by specialist retailers Your HVS Features Reduces condensation throughout the whole...

Страница 3: ...ng a typical day The sample was for the 10 5 08 and shows a minimum temp of 12 and a maximum of 28 degrees The actual outside minimum was just 10 8 and a maximum of just 17 on that day refer Appendix...

Страница 4: ...nto the home is required to banish condensation during winter The ventilation air supply positively pressurises the home causing stale air to be gently forced out through cracks under doors floor boar...

Страница 5: ...ufficient however if internal doors get closed extra outlets will be required The air from your Home Ventilation System is filtered for your protection The filter should to be replaced every 12 months...

Страница 6: ...speed dial controls the amount of air transferred during the ventilation mode which is the temperature range between SP1 and SP2 It can be manually varied between 30 and 100 of the fans air flow capa...

Страница 7: ...es If the condensation problem is very bad SP2 could be reduced to as low as 3 degrees but home heating would need to be increased If the condensation problem is only slight then SP2 could be set to a...

Страница 8: ...blems have the following performance guarantee If after 3 consecutive winter months the Customer is dissatisfied with the level of condensation control and the Customer has been adhering to all operat...

Страница 9: ...eck the filter f Do not use un flued gas heaters in the home g Ensure exhaust extraction fans are not dumping moisture into the roof space h Check for other sources of moisture that could effect the r...

Страница 10: ...Maximum Outlets HVS1 80 to 160 m 62 watts 45 135 l s 2 4 HVS2 120 to 240 m 80 watts 66 199 l s 2 6 HVS3 220 to 480 m 160 watts 132 398 l s 4 12 subject to change without notice Setting the Thermostat...

Страница 11: ...14 5 19 Mo 8 8 18 4 20 Tu 6 2 16 8 The following graph shows the roof space temperature at 108 Gormanston Road Moonah for the period 6 May 08 to 20 May 08 The blue line SP2 5 degrees and the red line...

Страница 12: ...ming air If the air temperature in the roof is the same as inside the house then obviously there is zero heat gain If the roof temp is greater than the inside air then there is a gain Conversely if th...

Отзывы: