BLOWER SPEED SELECTIONS
The UT Electronic Controls control boards have four quick con-
nect terminals for connecting the motor speed leads. These are:
1. FAN SPEED* — motor runs on this speed when the thermo-
stat is in the “FAN” position.
2. COOL — connect desired cooling speed.
3. HEAT — connect desired heating speed.
4. HEAT/COOL* — connect desired speed when heating and
cooling speed are the same.
5. If heating and continuous speed are the same, jump across
“FAN” and “HEAT” terminals.
GAS FURNACE (DIRECT DRIVE)
INSTRUCTIONS FOR CHANGING
BLOWER SPEED
The blower motor is wired for blower speeds required for normal
operation as shown.
If additional blower speed taps are available (leads connected to
“M1” and “M2” on the electronic control), speeds may be changed
if necessary to fit requirements of the particular installation. Re-
connect the unused motor leads to “M1” or “M2.” Check motor
lead color for speed designation.
Heating speeds should not be reduced where it could cause the
furnace air temperature to rise to exceed the maximum outlet air
temperature specified for the unit.
!
CAUTION
DO NOT CONNECT ANY MOTOR SPEEDS TO “HEAT” OR
“COOL” IF YOU USE THE “HEAT/COOL” TERMINAL. DOING
SO WILL DAMAGE THE BLOWER MOTOR. UNUSED
MOTOR WIRE TAPS MUST BE CONNECTED TO PARKING
TERMINALS M1 AND M2 OF THE IFC, OR PROPERLY IN-
SULATED.
!
WARNING
DISCONNECT THE ELECTRICAL SUPPLY TO THE FUR-
NACE BEFORE ATTEMPTING TO CHANGE THE BLOWER
SPEED. FAILURE TO DO SO CAN CAUSE ELECTRICAL
SHOCK RESULTING IN SEVERE PERSONAL INJURY OR
DEATH.
Low*
735 715 690 660 635 605 575
Med. Lo 1025 1015 995 975 955 930 905
Med. Hi 1185 1165 1150 1130 1100 1075 1040
High 1345 1330 1310 1295 1265 1235 1205
Low*
921 896 870 845 819 783 746
Med. Lo 1094 1066 1037 1014 990 949 907
Med. Hi 1239 1211 1182 1164 1146 1117 1087
High 1424 1398 1372 1339 1306 1267 1228
Low*
1210 1205 1195 1180 1165 1155 1130
Med. Lo 1580 1560 1550 1530 1495 1465 1430
Med. Hi 1915 1880 1825 1790 1740 1675 1600
High — 2050 1995 1940 1885 1835 1770
Low*
935 910 885 855 825 785 760
Med. Lo 1070 1055 1040 1010 980 945 905
Med. Hi 1240 1210 1190 1165 1135 1095 1055
High 1420 1395 1370 1340 1305 1265 1220
Low*
1330 1295 1285 1245 1225 1205 1160
Med. Lo 1690 1670 1655 1615 1585 1565 1525
Med. Hi — 2085 2055 2005 1970 1945 1880
High — 2410 2355 2305 2240 2165 2100
Low*
1330 1295 1280 1240 1215 1210 1175
Med. Lo — 1690 1660 1635 1580 1535 1480
Med. Hi — 2090 2035 1985 1930 1850 1785
High — 2395 2335 2260 2185 2080 1965
Low*
1300 1280 1230 1205 1170 1115 1030
Med. Lo 1675 1650 1620 1570 1545 1485 1425
Med. Hi 2105 2075 2035 1990 1955 1900 1815
High — 2340 2290 2215 2145 2080 1995
TABLE 8
AIR FLOW PERFORMANCE – (-)801S & (-)801P & (-)(-)80DSS/(-)(-)80DSP SERIES MODELS
Model
Motor HP [W]
Blower Size
IN [MM]
CFM Air Delivery
External Static Pressure, ” W.C. [kPa]
Speed Tap
0.1 [0.02]
0.2 [0.05]
0.3 [0.07]
0.4 [0.10]
0.5 [0.12]
0.6 [0.15]
0.7 [0.17]
(-)801SA050314ZSA
(-)801PA050314ZSA
(-)(-)80DSS050A30SA
(-)(-)80DSP050A30SA
1/2 [373]
11 x 6
[279 x 152]
(-)801SA075317ZSA
(-)801PA075317ZSA
(-)(-)80DSS075B30SA
(-)(-)80DSP075B30SA
(-)801SA075417ZSA
(-)801PA075417ZSA
(-)(-)80DSS075B40SA
(-)(-)80DSP075B40SA
(-)801SA100317ZSA
(-)801PA100317ZSA
(-)(-)80DSS100B30SA
(-)(-)80DSP100B30SA
1/2 [373]
11 x 7
[279 x 178]
3/4 [559]
11 x 7
[279 x 178]
1/2 [373]
11 x 7
[279 x 178]
(-)801SA100521ZSA
(-)801PA100521ZSA
(-)(-)80DSS100C40SA
(-)(-)80DSP100C40SA
3/4 [559]
11 x 10
[279 x 254]
(-)801SA125524ZSA
(-)801PA125524ZSA
(-)(-)80DSS125D50SA
(-)(-)80DSP125D50SA
3/4 [559]
11 x 10
[279 x 254]
(-)801SA150524ZSA
(-)801SA150524ZSA
(-)(-)80DSS150D50SA
(-)(-)80DSP150D50SA
3/4 [559]
11 x 10
[279 x 254]
*Not to be used on the heating speed tap.