ELECTRONIC AIR CLEANER
Line voltage power can be supplied from the terminal labeled
“EAC” and a line voltage neutral terminal on the control board.
This will power the electronic air cleaner whenever the circulating
air blower is in operation.
HUMIDIFIER
Line voltage power is supplied from the terminal labeled “HUM” to
a line voltage neutral terminal on the control board. This will
power the humidifier whenever the induced draft motor is ener-
gized.
NOTE:
Maximum current – 1.0 amps for each option (humidifier
or electronic air cleaner).
4-INCH FLUE ADAPTER
(See Figure 19)
Refer to “Venting” section of this manual for more information.
See
National Fuel Gas Code for sizing options.
FILTERS
(See Figure 20)
Keep filters clean at all times.
A filter is not provided with the
furnace, but one must be field-supplied and installed.
It is recommended to replace the furnace filter periodically to
maintain optimum furnace performance.
RXGW-B01 CHIMNEY ADAPTER
IMPORTANT:
CHIMNEY ADAPTER IS CERTIFIED FOR USE
ON (-)801S/(-)801P MODELS.
This appliance is CSA certified for use with RXGW-B01 Chimney
Adapter. Refer to Kit Installation Instructions 92-101682-01.
ACCESSORIES
FIELD INSTALLED OPTION ACCESSORIES
Ac
ce
ss
or
ie
s
DOWNFLOW
FIGURE 20
DOWNFLOW FILTER INSTALLATION
ST-A1220-27-00
1. STANDARD 3” FLUE CONNECTION.
2. 4” ADAPTER
SEE NATIONAL FUEL GAS CODE FOR SIZING OPTIONS