HSZ-600 STEREO MICROSCOPE 

[Applicable camera(image pickup device size) and field numbers] 

 

 

 

 

 

[Rotation of monitor image] 
The monitor image is rotated slightly because the right observation light path, which is tilted slightly, is used as 
the TV light path. 
The monitor image can be aligned with the observation image by rotating the TV camera. 

 

 

 

 

The TV camera light path incorporates a 0.5X lens.

 

FN 22 

(With 10X Eyepiece) 

 

2/3 in. image pickup device 

(Diagonal length 22mm) 

 

1/2 in. image pickup device 

(Diagonal length 16mm) 

 

Содержание HSZ-600

Страница 1: ...1 HSZ 600 STEREO MICROSCOPE ...

Страница 2: ...of publication HUVITZ assumes no responsibility however for possible errors or omissions or for any consequences resulting from the use of the information contained herein HUVITZ reserves the right to make changes in its products or product specifications at any time and without prior notice and is not required to update this documentation to reflect such changes 9000ENGO101 A 2010 HUVITZ Co Ltd 6...

Страница 3: ... 1 Stand 15 9 1 1 Using the Stage 15 9 1 2 Adjusting the Focus Adjustment Knob Tension Fig 1 15 9 1 3 Adjusting the light illumination 16 9 2 Microscope Body 16 9 2 1 Adjusting the interpupillary Distance Fig 2 16 9 2 2 Adjusting the Diopter Zoom Confocality Adjustment Fig 3 16 9 2 3 Using the Eye Shades Fig 4 18 9 2 4 Using an Eyepiece Micrometer Disk Fig 5 19 9 2 5 Selecting the Light Path Only ...

Страница 4: ...STEREO MICROSCOPE 12 Assembly 26 12 1 Assembly Diagram 26 12 2 Detailed Assembly Procedures 27 12 2 1 Installing the Microscope Body Fig 9 27 12 2 2 Mounting the Stage Plate Fig 10 11 27 13 Service Information 29 ...

Страница 5: ...nstall use clean service or adjust this equipment and any associated accessories It is paramount that the instructions contained in this manual are fully understood and followed to enhance safety to the patient and the user operator It is for this reason that the following safety notices have been placed appropriately within the text of this manual to highlight safety related information or inform...

Страница 6: ...es Disposal of your old appliance When this crossed out wheeled bin symbol is attached to a product it means the product is covered by the European Directive 2002 96 EC All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities The correct disposal of your old appl...

Страница 7: ...equipment is exposed to direct sunlight Where the temperature changes extremely Normal operating temperature range is from 10 C to 40 C Humidity is below 85 Altitude is from 700 to 1060hpa Where it is near the heat equipment Where the humidity is extremely high or there is a ventilation problem Where the equipment is subject to excessive shocks or vibrations Where equipment is exposed to chemical ...

Страница 8: ... 700 to 1060hpa of Altitude up to 2 000m 2 4 Safety Precautions This equipment has been developed and tested according to safety standards as well as national and international standards This guarantees a very high degree of safety for this device The legislator expects us to inform the user expressively about the safety aspects in dealing with the device The correct handling of this equipment is ...

Страница 9: ...ssory 9 Only persons who have undergone proper training and instructions are authorized to install use operate and maintain this equipment 10 Keep the User s Manual and Service Manual in a place easily accessible at all times for persons operating and maintaining the equipment 11 Do not force cable connections If a cable does not connect easily be sure that the connector plug is appropriate for th...

Страница 10: ... attachment and or photography unit are mounted on it Be careful so that the microscope does not topple down 3 Operating Condition As long as the device is in its original package it can be exposed to the following environmental conditions for up to 15 weeks for shipping and storage without risk of damage Temperature range from 40 C to 70 C Relative humidity range below 100 Class A equipment is in...

Страница 11: ...idity dust or vibrations Do not turn the zoom adjustment knobs beyond the stopper positions Otherwise the internal mechanism may be damaged Do not turn the left and right zoom adjustment knobs in the opposite directions as this will result in a failure 5 Maintenance and Storage To clean the lenses and other glass components simply blow dirty away using a commercially available blower and wipe gent...

Страница 12: ... in malfunction or reduced performance When disposing of the microscope Check the regulations and rules of your local government and be sure to observe them 6 Standard Components Standard composition of stereomicroscope is as following Microscope body HSZ 645 or HSZ 660 or HSZ 645TR Stand HSZ ST6 or HSZ ILST6 Eyepiece HSZ EPA10x When the light illumination of the stand is not working please check ...

Страница 13: ...ustment Knob Body Clamping Knob Auxiliary Objective mount thread Focus Adjustment Knob Stroke 120mm thread Accessory Mount Hole C mount clamping screw C mount Confocality Adjustment Clamping screw Light Path Selector Lever Pulled out TV Path 100 Right Eyepiece Sleeve Light Path 0 Pushed In Right Eyepiece Sleeve Light Path 100 ...

Страница 14: ...ment knob Prepare the light source as required 8 2 Procedure Place the specimen on the stage Page 15 Adjust the interpupillary distance Page 16 Adjust the eyepiece diopter Page 16 Set the zoom adjustment Knob for the lowest magnification and rotate the focus adjustment Knob to bring the specimen into approximate focus Rotate the zoom adjustment knob to the target magnification and rotate the focus...

Страница 15: ...obs with both hands fix the left knob and rotate the right Knob The rotation tension of the knob is increases or decreases according to the direction in which the right knob is rotated If the rotation tension is increased too much accurate focusing is not possible and the mechanism may be damaged Fig 1 This operation is intended to facilitate the rotation of the knobs while preventing spontaneous ...

Страница 16: ... binocular vision until the left and right fields of view coincide completely Fig 2 9 2 2 Adjusting the Diopter Zoom Confocality Adjustment Fig 3 Eyepieces without eyepiece micrometer disk 1 Turn the diopter adjustment rings of the left and right eyepieces to positions 0 This adjustment is not possible with eyepieces without helicoids 2 Place an easy to observe specimen on the stage plate Always h...

Страница 17: ... for low magnification look through the eyepiece with eyepiece micrometer disk and rotate the focus adjustment knob to bring the specimen into focus 4 Set the zoom adjustment knob for the highest magnification look through the eyepiece with micrometer disk and rotate the focus adjustment knob to bring the specimen into focus 5 Set the zoom adjustment knob for the lowest magnification and rotate th...

Страница 18: ...l prevent the eyeglasses from being scratched Diopter scale of the 10X eyepieces The valid range of the diopter scale is between 8 and 5 but a slight margin is added to it Therefore the diopter value may exceed 5 or 8 when it is adjusted to the maximum ln this case whether the diopter value is over 8 or under 5 can be identified by the length of the eyepiece ...

Страница 19: ...nterclockwise to remove 2 Prepare an eyepiece micrometer disk remove dust and dirt from its surface and fit it into the disk mounting ring so that the engraving on the micrometer disk faces downward 3 Gently screw in the disk mounting ring incorporating the eyepiece micrometer disk into the eyepiece Turn the ring clockwise to attach it firmly When the eyepiece micrometer disk is not used store it ...

Страница 20: ... each zoom magnification value indicated on the zoom magnification indication 2 To switch the click stop function OFF turn the click stop screw counterclockwise in the opposite direction to the arrow by about 2 turns using the Allen screwdriver Light Path Selector Knob Indication Light Path Ratio Pushed in position Binocular 100 Pulled in position TV Photo 100 The click stop function provides a cl...

Страница 21: ...ctor lever and set the magnification to the minimum 3 Slightly loosen the two confocality adjustment clamping screws and C mount clamping screw 4 Hold the TV camera and rotate the confocality to focus on the monitor image After the adjustment tighten the clamping screw and Fig 8 To prevent damaging the microscope cover and internal mechanism do not turn the screw excessively ...

Страница 22: ...ly because the right observation light path which is tilted slightly is used as the TV light path The monitor image can be aligned with the observation image by rotating the TV camera The TV camera light path incorporates a 0 5X lens FN 22 With 10X Eyepiece 2 3 in image pickup device Diagonal length 22mm 1 2 in image pickup device Diagonal length 16mm ...

Страница 23: ... Visibility of observed image is poor Dirt dust on the dustproof glass on the tip of the objective Clean Thoroughly 11 4 Zooming causes defocusing of the observed image The eyepiece diopter is adjusted improperly Adjust it correctly 16 17 The focus adjustment is inaccurate Adjust the focus accurately 14 5 The focus adjustment knob does not rotate smoothly The rotation tension of the knob is set to...

Страница 24: ...8 Stand HSZ ST6 HSZ ILST6 Standard large stand LED reflected transmitted illumination large stand HSZ ST6 Frame installation Mounting diameter 76mm HSZ ILST6 Focusing adjustment Knob rotation tension adjustment Focusing stroke 120mm Stage plate HSZ SPG160 HSZ SPG160 HSZ SPBW160 Light source Transmitted illumination LED Reflected illumination LED Average LED life span 10 000 hrs POWER Input rating ...

Страница 25: ...25 ...

Страница 26: ...bly of the various modules When assembling the microscope make sure that all parts are free of dust and dirt and avoid scratching any parts or touching glass surfaces Eye Pieces C Mount Camera Microscope Body Other HSZ 645TR Standard Base Eye Piece Clamping knobs Microscope Body Stage Plate Body Clamping Knob ...

Страница 27: ...t it faces frontward and tighten the body clamping knob Fig 9 12 2 2 Mounting the Stage Plate Fig 10 11 1 To mount the stage plate fit the stage plate into the stage plate mounting hole 2 To dismount the stage plate push the stage plate edge As this move up the opposite edge of the stage plate dismount it by holding that edge The stage plate has the milky white and black surfaces Select the side f...

Страница 28: ...28 HSZ 600 STEREO MICROSCOPE Fig 10 Fig 11 Mounting Dismounting ...

Страница 29: ...following information Name of the product HSZ 600 Serial number of the product refer to the 9 digit number on its product label or name plate Descriptions of Problem In detail Date of Purchase Dealer s Name Dealer Address Dealer Phone No Version No Serial No Huvitz recommends customers to fill up the above form after purchase and retain this manual as a permanent record of purchase Write us at HUV...

Отзывы: