roubleshooTinG
Trouble
Possible cause
Corrective action
Compressor won’t start
1 Blowen fuse or Circuit breaker
tripped.
2. Loose electrical connections
1. Replace or Reset Fuse/ Circuit
Breaker
2. Check Wiring connections
Low Pressure
1. Restricted Air Filter
2. Defective Check Valve
3. Air Leak in Safety Valve
1. Replace Air filter
2. Replace Air Valve
3. Check Valve by pulling upwards
on ring. If condition persists,
replace valve.
Safety Valve Releasing
1. Defective Pressure Switch
1. Replace Pressure Switch
Oil Discharge in Air
1. Improper Oil Viscosity
2. Too much oil in Crankcase
3. Compressor over heated
4. Restricted oil Breather
1. Replace oil with SAE20 or SAE30
no-detergent oil.
2. Drain Crankcase and refill to
proper level on Oil Sight Glass
3. Reduce air pressure regulation
4. Clean or Replace Oil Breather.