HUST CNC H6D-B3 MANUAL
77
Check the program or revise the settings in
『
Parameter page 1
』
for software travel
limit.
ERROR-22
Em-Stop, Home Again
Message: Controller is in emergency stop state.
Recommended Remedy:
Resolve the cause for emergency stop. Restore Emergency-STOP button and press
RESET.
ERROR-30.1
BATT.LOW
Message: The battery (BT1) for data storage is out of charge or service.
Recommended Remedy:
Replace the battery BT1or power on for 5 hours.
ERROR-31
None PLC
Message: There is no PLC ladder program in the memory.
Recommended Remedy:
Contact the engineer.
ERROR-51
Message:
The machine coordinate of X(L)-axis > The setting of software OT +.
Recommended Remedy:
Ascertain the value of Parameter page 1
『
Software OT +1
』
.
ERROR-52
Message:
The machine coordinate of X(L)-axis < The setting of software OT
-
.
Recommended Remedy:
Ascertain the value of Parameter page 1
『
Software OT
-
1
』
.