LEVELING OF THE CABINET
Cabinets must be installed level to ensure proper operation of the refrigeration system and to ensure proper
drainage of defrost water. When leveling merchandisers, use a carpenter’s level as shown
SEALING SPLASHGUARD TO FLOOR
If required by local sanitation codes, or if desired by the customer, stainless steel splashguards may be sealed to
the floor using a vinyl cove base trim. The size of trim needed will depend on how much the floor is out of
level.
To install the trim to the splashguard:
1. Remove all dirt, wax and grease from the area of the splashguard where adhesion will be necessary.
This is to ensure a good and secure installation.
2. Apply a good contact cement to the cove trim and allow proper drying time according to the directions
supplied with the cement.
3. Install the trim to the splashguard so that it is lying flush with the floor. DO NOT SEAL THE TRIM
TO THE FLOOR.
4.
If required by local health codes
the cove Trim may be sealed to the floor, using a silicone-type sealer.
Sealant must be removed and replaced when servicing the case condensing unit area.