Routine maintenance
a) Verify that the blades of the evaporator and condenser motors rotate freely and that the motors work
correctly.
b) Verify that the drainage is not obstructed and the hoses in the condenser pan avoid spills of water after
defrost
c) Makes sure that the doors close easily and seal well
d) Make sure the discharge honeycomb and the return grill are free of ice. The discharge honeycomb is
removable for cleaning.
TECHNICAL DATA SHEETS
The data sheets are enclosed with this manual inside the cabinet. The data sheets contain electric specifications
of the cabinet, electric diagrams, lists of parts and operation data.