4-2
M
aintenance
P/N 2400204_H
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • www.hussmann.com
CLEANING STAINLESS STEEL SURFACES
Use non-abrasive cleaning materials, and
always polish with grain of the steel. Use warm
water or add a mild detergent to the water and
apply with a cloth. Always wipe
rails dry after wetting.
Use alkaline chlorinated or non-chlorine
containing cleaners such as window cleaners
and mild detergents. Do not use cleaners
containing salts as this may cause pitting and
rusting of the stainless steel finish. Do not
use bleach.
CLEANING PENCIL THERMOMETER
NAV/C models have pencil thermometers.
The thermometer is located at the top, front
center of the merchandiser’s cabinet interior.
To clean the thermometer:
1. Remove the two screws securing the
thermometer to its mounting bracket.
2. Remove the plastic ends from the
thermometer. Then, slide out the glass
tube.
3. Use non-abrasive cleaning materials and
a mild detergent to clean glass tube and
thermometer cover.
4. Replace thermometer.
Pencil Thermometer
Do NOT use HOT water on Cold glass Surfaces.
This can cause the glass to shatter and could
result in personal injury. Allow glass fronts, to
warm before applying hot water.
DO NOT FLOOD!
Use only enough water necessary to clean
surface. Water must not drip down the case!
Never use ammonia based cleansers, abrasive
cleansers, or scouring pads.
— LOCK OUT / TAG OUT —
To avoid serious injury or death from electri-
cal shock, always disconnect the electrical
power at the main disconnect when servicing
or replacing any electrical component. This
includes, but is not limited to, such items as
doors, lights, fans, heaters, and thermostats.