P/N 2400204_H
2-5
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
Service Deli Merchandisers
DEFROST TERMINATION SWITCH
Merchandisers may use a defrost termination
switch, instead of an evaporator sensor to
terminate a defrost cycle. The defrost
termination switch is temperature activated
and senses the completion of defrost.
MANUAL DEFROST
Note:
This procedure initiates
a manual or forced
defrost.
IMPORTANT:
Return the control knob to its original setting
(Step 1) once the manual defrost has been ini-
tiated.
On
Off
Time
Off
On
Off
On
Com pressor
O ff Tim e If
Sensor Failed
Com pressor
O n Tim e If
Sensor Failed
Com pressor or
Refrigeration
Status
1
2
3 4 5
6
7
I
I
Warm
Cold
Rotate knob fully
counterclockwise
until it stops (full
2.
1
2
3 4 5
6
7
I
I
Warm
Cold
Note location of
knob setting
1.
1
2
3 4 5
6
7
I
I
Warm
Cold
3.After 10 seconds, but
before 20 seconds,
rotate knob fully
clockwise until it
stops (full cold position)