cleaning glass and Mirrors

Only  use  a  soft  cloth  and  water  for  cleaning  any  glass 

or  mirrored  components.  Be  sure  to  rinse  and/or  dry 

completely.

never use hot water on cold glass surfaces! it may 

shatter and cause serious injury!

 Allow glass surfaces 

to warm first.

Plexiglass and acrylic care

Improper cleaning not only accelerates the cleaning cycle 

but also degrades the quality of this surface. Normal daily 

buffing motions can generated static cling attracting dust 

to the surface. Incorrect cleaning agents or cleaning cloths 

can  cause  micro  scratching  of  the  surface,  causing  the 

plastic to haze over time.

cleaning

Hussmann recommends using a clean damp chamois, or a 

paper towel marketed as dust and abrasive free with 

210

®

 

Plastic cleaner and Polish

 available by calling Sumner 

Labs at 

1-800-542-8656

. Hard, rough cloths or paper towels 

will scratch the acrylic and should not be used.

antistatic coatings

The 

210

®

  has  proven  to  be  very  effective  in  not  only 

cleaning  and  polishing  the  Plexiglas  surface,  but  also 

providing anti-static and anti-fog capabilities. This product 

also seals pores and provides a protective coating.

Maintenance

BEFORE SERVICING

Disconnect both Attachment Plugs to 

completely De-energize unit.

 

Failure to disconnect both plugsmay result in 

damage to equipment, serious personal injury!

This includes (but not limited to) Fans, Heaters,

Thermostats and Lights.

Replacing fluorescent lamps

Fluorescent lamps are furnished with moisture resistant 

lamp holders, shields and end caps. Whenever a florescent 

lamp is replaced, be certain to reinstall the lamp shield and 

end caps over the lamp. The lamps supplied are single 

slim-line or bi-pin type with or without starters.

ENCAPSULITE

SHATTERPROOF COATING - SA 10645

Complies with FDA USDA

& OSHA Regulations

for replacement call:

1-800-395-9229

Turn switch off then on after replacing bulb

NSF

U R

R

evaporator fans

The evaporator fans are located at the center front of these 

merchandisers directly beneath the display pans.

copper coils

The copper coils used in Hussmann merchandisers may 

be repaired in the field. Materials are available from local 

refrigeration wholesalers.
Hussmann recommends using #15 Sil-Fos for repairs.

tips and troubleshooting

Before calling for service, check the following:

1.   Check electrical power supply to the equipment for 

connection.

2.   Check fixture loading. Overstocking case will affect 

its proper operation.

3.   If frost is collecting on fixture and/or product, check 

that no outside doors or windows are open- allowing 

moisture to enter store. 

FOR PROMPT SERVICE

When Contacting the Factory regarding problems.

 Be sure to have the Case MODEL and 

SERIAL NUMBER Handy. This Information 

is on a plate located on the case itself.

user information (cont'd)

Содержание MZ3-S

Страница 1: ...S Multi zone Refrigerated Self Service Self Contained P N IGSS MZ3 S 0909 INSTALLATION OPERATION GUIDE CHINO MZ3 S MULTI ZONE REFRIGERATED SELF SERVICE SELF CONTAINED Rev 0909 Installation Operation Manual ...

Страница 2: ...ely and request an inspection Hussmann Chino will acknowledge shortages within ten days from receipt of equipment HUSSMANN CHINO PRODUCT CONTROL The serial number and shipping date of all equipment has been recorded in Hussmann s files for warranty and replacement part purposes All correspondence pertaining to warranty or parts ordering must include the serial number of each piece of equipment inv...

Страница 3: ...71 6 20 1 4 18 1 4 16 1 4 37 1 4 30 7 8 27 5 8 19 3 4 10 7 8 9 3 8 9 3 8 1 5 8 1 7 8 1 7 8 1 5 8 50 3 8 47 1 4 37 1 4 6 ELECTRICAL CONNECTION 2 POWER CORDS 1 NEMA 5 15P 2 NEMA L5 20P MZ3 4S PLAN VIEW RCD FMSS LT Condensing Unit MZ3 SELF SERVICE MERCHANDISER ...

Страница 4: ...Case must be raised correctly under legs where support is best to prevent damage to case 1 Check level of floor where cases are to be set Determine the highest point of the floor cases will be set off this point 2 Level and set the case Case must be raised under legs where support is best to prevent damage to case Internal bracing may be removed at this time It is the contractor s responsibility t...

Страница 5: ...r location Control Settings self Contained All functions are controlled by Omni Stat Controllers See MZ3 S Technical Data Sheet for proper temperature and defrost settings Access to TX Valves and Drain Lines MECHANICAL Remove product from end of case Remove product racks Remove refrigeration and drain access panels labeled TX valve mechanical only and drain are located under each access panel at e...

Страница 6: ...rol temp Btu hr ft Parallel 400 Conventional 460 Low Temp Discharge Air F 10 Evaporator F 20 Note Not recommended to control temp by regulating coil temp allow T STAT to cycle and control temp Btu hr ft Parallel 600 Conventional 690 For all refrigeration equipment other than Hussmann use conventional Btu values Defrost Data Frequency Hrs 8 OFFTIME Temp Term F 54 Failsafe Minutes 30 ELECTRIC or GAS...

Страница 7: ...both cords before moving or servicing this equipment Attachment Plugs This unit contains two power supply cords Each cord is a different type Connect each plug to a single outlet circuit The first attachment plug is a NEMA 5 15P type plug with a 15 amp rating A 15 amp line is required for the NEMA 5 15P plug The second is a NEMA L5 20P type plug with a 20 amp rating A 20 amp line is require for th...

Страница 8: ...t dehydration Recommended Omni Stat Temperature Control Settings RCD 26 FMSS LT 15 See Case Specifications for Details 2 Temperature control is adjusted by the Omni Stat Temperature Controller Case Cleaning Long life and satisfactory performance of any equipment are dependent upon the care given to it To insure long life proper sanitation and minimum maintenance costs the refrigerator should be th...

Страница 9: ...t in damage to equipment serious personal injury This includes but not limited to Fans Heaters Thermostats and Lights Replacing Fluorescent Lamps Fluorescent lamps are furnished with moisture resistant lamp holders shields and end caps Whenever a florescent lamp is replaced be certain to reinstall the lamp shield and end caps over the lamp The lamps supplied are single slim line or bi pin type wit...

Страница 10: ...t safe and use a soft cloth or plastic scouring pad 3 Use Alkaline Alkaline Chlorinated or Non chloride Containing Cleaners While many traditional cleaners are loaded with chlorides the industry is providing an ever increasing choice of non chloride cleaners If you are not sure of your cleaner s chloride content contact your cleaner supplier If they tell you that your present cleaner contains chlo...

Страница 11: ...15V 60 Hz 952892 125 01 2304 AIR TEMP DEFROST TEMP 125 01 2301A MAX 16 FEET N GROUND FAN COMP 1 DEFROST SOLENOID 225 01 6004 225 01 6005 M M PRESSURE SAFETY CONDENSING UNIT C R BLACK 14 WHITE 14 LOWER HOT GAS DEFROST SECTION CONDUCTIVE GLASS HEATER 10 W FT 120VAC 40W 33A 150 01 7850 WARMER 4ft 125 01 0767 10BTV1 CR 40 WATTS 0 33AMP 120V BLACK 14 L1 N OMNI STAT PN 952896 120VAC POWER SUPPLY 115Vac ...

Страница 12: ...YELLOW DM10W 1D 1000W 120 VAC 8 33A 125 01 0758 SAFETY SWITCH FLOAT SWITCH PLUG NEMA 5 15P G BLACK 14 WHITE 14 DUPLEX 125 01 0096 CIRCUIT 2 PLUG NEMA 5 15P 125 01 0986 CIRCUIT 1 F28T5 48 125 03 1132 BALLAST 125 01 3266 FULHAM LH3 120 L TOGGLE SWITCH 125 01 0307 BALLAST 125 01 3266 FULHAM LH3 120 L LIGHT CIRCUIT 1 56A 168W BALLAST 125 01 3266 FULHAM LH3 120 L F28T5 48 125 03 1132 F28T5 48 125 03 11...

Страница 13: ...v 0 F v 10 F v 30 F v 110 F v 90F 0 F v 106 F v 80 F v 80 F v 80 F v 2000 BTU h 15 F v 2000 BTU h 20 F v ZONE 1 ZONE 2 Condenser Heat Exchanger Compressor Evaporator Evaporator Check Valve TXV TXV 4 way valve Accumulator Receiver EPR Liquid Stop Check Valve Check Valve ...

Страница 14: ...ete start up evaluation prior to the loading of food into the refrigerator which includes such items as a Initial temperature performance Coils should be properly fed with a refrigerant according to Hussmann recommendations b Observation of outside influences such as drafts radiant heating from the ceiling and from lamps Such influence should be properly corrected or compensated for c At the same ...

Страница 15: ...Are spotlights or other high intensity lighting directed onto the product 7 Are there unusual draft conditions from heating air conditioning ducts open doors etc 8 Is there exposure to direct sunlight 9 Are display signs blocking or diverting airflow 10 Are the coils of the refrigerator iced up 11 Is the store ambient over 75 F 55 RH as set forth in ASHRAE Standard 72 and ASHRAE Standard 117 12 Ar...

Страница 16: ...Care must be taken when cross merchandising products to ensure that potentially hazardous vegetable products are not placed in non refrigerated areas e Display and storage equipment doors should be kept closed during periods of inactivity f Minimize the transfer time of perishables from storage to display g Keep meat under refrigeration in meat cutting and processing area except for the few moment...

Страница 17: ..._________________________________ _______________ ___________________________________________________________________________________________________ _______________ ___________________________________________________________________________________________________ _______________ ___________________________________________________________________________________________________ _______________ __...

Отзывы: