igSS-Mz3-S-0909
6
ELECTRICAL CONNECTION
2 POWER CORDS
1. NEMA 5-15P
2. NEMA L5-20P
MZ3-4S
PLAN
RCD
FMSS-LT
Condensing
Unit
MZ3
SELF SERVICE MERCHANDISER
OMNI-STAT
TEMPERATURE
CONTROLLER
&
BALLASTS
OMNI-STAT
TEMPERATURE
CONTROLLER
&
BALLASTS
ACCESS
COVER
FRONT
Refrigeration (cont'd)
Refrigeration data
note:
this data is based on store temperature and humidity
that does not exceed 75f and 55% R.H.
discharge air (f) 28
evaporator (f)
20
note:
not recommended to control temp by regulating coil
temp allow t-Stat to cycle and control temp.
Btu/hr/ft*
Parallel
400
conventional
460
low temp
discharge air (f) -10
evaporator (f)
-20
note:
not recommended to control temp by regulating coil
temp allow t-Stat to cycle and control temp.
Btu/hr/ft*
Parallel
600
conventional
690
*For all refrigeration equipment other than Hussmann, use
conventional Btu values.
defrost data
frequency Hrs
8
offtiMe
temp term °f
54
failsafe Minutes
30
electRic or gaS not Recommended
Physical data
Merchandiser Drip Pipe (in.)
1½
Merchandiser Liquid Line (in.)
3/8
Merchandiser Suction Line (in.)
5/8
Estimated Charge (lb)***
4ft
1.
5ft
1.5
6ft
1.8
*** This is an average for all refrigerants types. Actual
refrigerant charge may vary by approximately half a
pound.
glycol Requirements
gPM
PSi
n/a
n/a