background image

RLNI with 

Innovator Doors

Technical Data Sheet 

4 of 6

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Electrical Data

2Dr

3Dr

4Dr

5Dr

Number of Fans—12W

2

3

4

5

Amperes

Watts

Merchandiser

2Dr

3Dr

4Dr

5Dr

2Dr

3Dr

4Dr

5Dr

Evaporator Fan

120V

60Hz

Standard

1.30

1.95

2.60

3.25

100

150

200

250

120V

50Hz

Standard

1.50

2.25

3.00

3.75

114

171

228

285

220V

60Hz

Export

0.66

0.99

1.32

1.65

100

150

200

250

220V

50Hz

Export

0.76

1.14

1.52

1.90

114

171

228

285

120V

60Hz

Energy Efficient

0.60

0.90

1.20

1.50

36

54

72

90

220V

60Hz

Energy Efficient

0.30

0.45

0.60

0.75

36

54

72

90

Door Anti-sweat Heaters (on fan circuit)

120V

50/60Hz Standard

1.54

2.31

3.08

3.86

185

278

370

463

220V

50/60Hz Export

0.84

1.26

1.68

2.10

185

278

370

463

Frame Anti-sweat Heaters (on fan circuit)

120V

50/60Hz Standard

0.78

1.18

1.57

1.97

94

141

188

236

220V

50/60Hz Export

0.43

0.64

0.85

1.07

94

141

188

236

Minimum Circuit Ampacity

120V

60Hz

Standard

3.82

5.64

7.45

9.28

120V

50Hz

Standard

4.02

5.94

7.85

9.78

220V

60Hz

Export

2.13

3.09

4.05

5.02

220V

50Hz

Export

2.23

3.24

4.25

5.27

120V

60Hz

Energy Efficient

3.12

4.59

6.05

7.53

220V

60Hz

Energy Efficient

1.77

2.55

3.33

4.12

Maximum Over Current Protection 120V

20

20

20

20

Maximum Over Current Protection 220V

15

15

15

15

Defrost

Drain Heaters (120V)

0.63

1.25

2.00

2.57

75

150

240

300

(Export: 220V 50 Hz)

0.34

0.76

1.22

1.53

84

168

269

336

208V 1Ø

Electric Defrost

6.72

10.08

13.46

16.82

1400

2100

2800

3500

(Export: 220V 50 Hz)

7.11

10.66

14.24

17.79

1564

2345

3133

3914

Standard Vertical Lighting

2Dr

3Dr

4Dr

5Dr

2Dr

3Dr

4Dr

5Dr

Innovator* Doors

(120V)

1.50

2.00

2.50

3.00

180

240

300

360

(Export: 220V 50 Hz)

0.84

1.12

1.40

1.68

185

246

308

370

Optional LED Lighting (120V)

0.87

1.16

1.45

1.74

105

140

174

209

*

Innovator 

or  

Innovator II

ELECTRICAL DATA IS PER SIDE — TWO CIRCUITS REQUIRED PER CASE.

Hussmann recommends against frame heater cycling with
Innovator doors to prevent door seals from freezing to the
frames and tearing. 

Impact  

RLNI

With INNOVATOR Doors