background image

RLNI with 

Innovator Doors

Technical Data Sheet 

2 of 6

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

5

 

3

/

8

 

(142)

Refrig. Outlet

A

C

B

Front Relay & Terminal 

 Block Location

Front 

5-Door Shown

6

 

(152)

 (see note *)

Water Seal  (see note **)

63

 

1

/

8

 

(1603)

67

 

7

/

8

 

(1724)

72

 

1

/

4

 

(1835)

60

 

1

/

2

 

(1537)

Electrical Wireway

70

 

1

/

8

 

(1780)

Bottom Front 
Support

48

 

(1219)

(76)

(102)

Waste Outlet

Skid/External Base

Reach-in Narrow Island 

2, 3, 4, & 5 Door

08/2002

Engineering Plan Views

RLNI 

Plan View

Electrical Wireway

(76)

(102)

D

Refrig. Outlet

Rear Relay & Terminal Block Location

Dimensions shown as in. & (mm).

Serial Plate attached to top left front of each case.

2 Dr

3 Dr

4 Dr

5 Dr

General

(A)

Case Length 

(without ends or partitions)

62 (1575)

92 

1

/

2  

(2350)

122 

7

/

8  

(3121) 153 

3

/

8  

(3896)

Maximum O/S dimension of case back to front

72 

1

/

4  

(1835)

72 

1

/

4  

(1835)

72 

1

/

4  

(1835)

72 

1

/

4  

(1835)

(Includes bumper)

Back of case to rear of splashguard

67 

7

/

(1724)

67 

7

/

(1724)

67 

7

/

(1724)

67 

7

/

(1724)

Width of Skidrail

1

/

(114)

1

/

(114)

1

/

(114)

1

/

(114)

Width of Bottom Front Support

6 (152)

6 (152)

6 (152)

6 (152)

Stub-up area between front skidrail and splashguard

3

/

(1000)

3

/

(1000)

3

/

(1000)

3

/

(1000)

Electrical Service 

RH end of case to the center of nearest knockout

4 (102)

4 (102)

4 (102)

4 (102)

(B)

RH end of case to the center of LH knockout

58 (1473)

88 

1

/

2  

(2248)

118 

7

/

8  

(3019) 149 

3

/

8  

(3794)

Back O/S of case to center of knockout

70 

1

/

(1780)

70 

1

/

(1780)

70 

1

/

(1780)

70 

1

/

(1780)

* NOTE: Electrical Field Wiring Connection Point is at terminal.

Waste Outlet

(C)

Right end of case to center of waste outlet

23 

3

/

(603)

54 

1

/

(1378)

46 

1

/

(1175)

76 

5

/

(1946)

Back O/S of case to center of waste outlet

63 

1

/

(1603)

63 

1

/

(1603)

63 

1

/

(1603)

63 

1

/

(1603)

Water Seal

Edge of water seal to center of waste outlet

11 (279)

11 (279)

11 (279)

11 (279)

Outside diameter of drip piping

1

/

(32)

1

/

(32)

1

/

(32)

1

/

(32)

** NOTE: Field installed water seal outlets, tees, and connectors are shipped with case

Refrigeration Outlet

RH end of case to center of RH refrigeration outlet

3

/

(137)

3

/

(137)

3

/

(137)

3

/

(137)

Back O/S of case to center of refrigeration outlet

60 

1

/

(1537)

60 

1

/

(1537)

60 

1

/

(1537)

60 

1

/

(1537)

(D)

Outside bottom front supports from end of case

3

/

4

(170)

3

/

4

(170)

3

/

4

(170)

3

/

4

(170) 

Center bottom front support from Centerline

24 (610)

24 (610)

24 (610)

24 (610)

Distance between Center and Outside supports will vary

01-2003

Отзывы: