background image

REFRIGERATION DATA

Note: 

This data is based on store

temperature and humidity that does not
exceed 75

°

F and 55% R.H.

FF

IC

Discharge Air (°F)

–5

–12

Evaporator(°F)

–11

–19

Unit Sizing (°F)

–14

–22

Btu/hr/door/side*

FF

IC

Parallel

1180

1244

Conventional

1200

1270

*Optional LED lighting reduces the
refrigeration load by 100 Btu/hr/Door.

DEFROST DATA

FF

IC

Frequency (hr) 

24

24

Defrost Water 

(lb/Dr/side/day)

1.2

1.2

(± 15% 

based on case configuration and

product loading).

E

LECTRIC

FF

IC

Temp Term (°F)

48

°

48

°

Failsafe (minutes)

45

45

G

AS

Duration 

(minutes)

20

20

O

FFTIME

Not Recommended 

CONVENTIONAL CONTROLS

Low Pressure Backup Control

FF

IC

CI/CO (Temp °F)

**

–18°/ –34°  –26°/ –45°

Indoor Unit Only, Pressure Defrost
Termination (Temp °F)

**

Not Recommended

**Use a Temperature Pressure Chart to
determine PSIG conversions.

PHYSICAL DATA

Drip Pipe (in.)

1

/

4

Liquid Line (in.)

3/8

Suction Line (in.)

7/8

Estimated Charge per Side (lb)***

2Dr

1.8

3Dr

2.7

4Dr

3.6

5Dr

4.6

***This is an average for all refrigerant
types. Actual refrigerant charge may vary
by approximately half a pound.

Length Added to Lineup by each 
Standard End (in.)

2

Optional End with Window (in.)

1

/

2

Optional Partition (in.)

1

/

2

Impact  

RLNI

With 

INNOVATOR Doors

Frozen Food & Ice Cream

3 of 6

P/N 0435492_G

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

72

 

 (1835) 

67

 

 (1724) 

70

 

 (1780) 

63

 

 (1603) 

60

 

 (1537)

4

 

 

(121)

9

 

 

(232)

11

 

 

(281)

82

 

3

/

8

  

(2091)

83 

1

/

2

 

(2120)

Dimensions shown as in. & (mm).

NSF Certification:  

These merchandisers are manufactured to meet 

ANSI/National Sanitation Foundation (NSF

®

) Standard #7 requirements. 

Reach-in Narrow Island 2, 3, 4 and 5 Door Models
INNOVATOR Doors Standard

Refrigeration data is PER SIDE.