REFRIGERATION DATA
Note:
This data is based on store temperature and
humidity that does not exceed 75
°
F and 55% R.H.
D5XRRIS
Discharge Air (°F)
32
Evaporator (°F)
21
Unit Sizing (°F)
19
Important Note:
Btu numbers are for the
D5XRRI when installed to a cooler operating at a
36
°
F air temperature. The unit cooler coil must
be sized for an
additional load of 800 Btu/hr/ft
of D5XRRI
case installed to the cooler.
Btu/hr/ft
D5XRRIS
Roll-in Dairy Carts
Parallel
Conventional
U
NLIT
1035
1200
DEFROST DATA
D5XRRIS
Frequency (hr)
6
Defrost Water (lb/ft/day)
6
(± 15%
based on case configuration and
product loading).
O
FF
T
IME
D5XRRIS
Time Terminated (minutes)
50
E
LECTRIC OR
G
AS
Not Recommended
Standard Defrost Thermostat — NA
CONVENTIONAL CONTROLS
Low Pressure Backup Control
D5XRRIS
CI/CO (Temp °F)
*
14 / 4
Indoor Unit Only, Pressure Defrost
Termination (Temp °F)*
NA
*Use a Temperature Pressure Chart to
determine PSIG conversions.
Estimated Charge (lb)**
6 ft
2.0
8 ft
2.7
12 ft
3.9
**This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.
P/N 0468269_B
Coil
Fan
Fan
D5XRRIS
Cooler Wall
81
3
/
4
(2077)
79
5
/
8
(2022)
32
1
/
8 (815)
44
3
/
4 (1137)
46
1
/
2 (1179)
47
1
/
2 (1205)
54
3
/
4
(1390)
17
1
/
2
(444)
19
7
/
8
(504)
4
1
/
2
(115)
34
3
/
4 (882)
47
5
/
8 (1208)
10
5
/
8
(269)
12
5
/
8
(321)
1
(26)
C
O
O
L
E
R
W
A
L
L
4
1
/
8 (106)
44
(1117)
85
3
/
4
(2178)
Impact
D5XRRIS
Dairy
Dimensions shown as in. & (mm).
Suspended, Roll-in Rear Load
3 of 7
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF
(National Sanitation Foundation) Standard #7 requirements for
construction, materials & cleanability.