background image

D5XRRIS 

Technical Data Sheet 

6 of 7

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

2

120V N

EUTRAL

B

ROWN

  B

AND

120V P

OWER

Fans 1

B

ROWN

  B

AND

Refrigeration 

Thermostat

To 
Condensing 
Unit

}

Light Blue

3

4 & 6 Discharge Air Fans

connectors

connectors

5

4

connectors

G

R

B L

B L

R

G

5

B L

R

B L

W

B

G

B

connectors

W

5

4

connectors

G

R

B L

B L

R

G

5

B L

R

B L

5

4

connectors

G

R

B L

B L

R

G

5

B L

R

B L

Optional Shelf Harness 

 and Light Circuits 

 

R = Red     G = Green  BL = Blue   B = Black   W = White

=  120V P

OWER

=  120V N

EUTRAL

=  Field G

ROUND

=  Case G

ROUND

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded. 

Circled Numbers = Parts List Item Numbers 

2

120V N

EUTRAL

B

ROWN

  B

AND

120V P

OWER

Fans 1

B

ROWN

  B

AND

4 & 6 Return Air Fans

12 ft

12 ft

12 ft

Fan Wiring
Offtime Defrost

Содержание IMPACT Excel D5XRRIS

Страница 1: ...Discharge 0477656 Fan Motor Discharge MO 4410547 0463643 Fan Blade FB 4780648 B 12W Standard Fan Assembly Return 2 0047000 Fan Motor Return MO 4410103 0315470 Fan Blade FB 0315470 12W Energy Efficient...

Страница 2: ...3 1 8 79 Waste Outlet D End of case to the center of waste outlet canopy drip pipe 1 1 4 32 1 1 4 32 1 1 4 32 Outside diameter of the drip pipe 7 8 22 7 8 22 7 8 22 Refrigeration Outlet Back of case c...

Страница 3: ...Low Pressure Backup Control D5XRRIS CI CO Temp F 14 4 Indoor Unit Only Pressure Defrost Termination Temp F NA Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb 6 ft 2...

Страница 4: ...72 120V 50Hz Standard 7 12 7 12 10 58 230V 60Hz Export 3 08 3 08 4 52 230V 50Hz Export 3 64 3 64 5 36 120V 60Hz Energy Efficient 2 60 2 60 3 80 230V 60Hz Energy Efficient 1 40 1 40 2 00 Maximum Over...

Страница 5: ...t Ft 15 43 ft3 ft 1 43 m3 m Total Display Area 3 Sq Ft Ft 4 79 ft2 ft 1 46 m2 m Shelf Area 4 Sq Ft Ft 2 69 ft2 ft 0 82 m2 m 1 Refrigerated Volume ft3 m3 Unit of Length ft m 2 Refrigerated Volume less...

Страница 6: ...W B G B connectors W 5 4 connectors G R B L B L R G 5 B L R B L 5 4 connectors G R B L B L R G 5 B L R B L Optional Shelf Harness and Light Circuits R Red G Green BL Blue B Black W White 120V POWER 1...

Страница 7: ...BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Optional Lighting 1 Row Rail 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL 5 R R BL BL 4 BL R R...

Отзывы: