background image

7 of 8

P/N 0480109_C

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

5

4

5

5

5

5

B

W

BL

BL

R

BL

R

BL

R

BL

W

R

W

R

B

R

BL

BL

R

4

B

BL

BL

BL

BL

BL

R

R

R

R

R

 

 

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

=  120V P

OWER

=  120V N

EUTRAL

=  F

IELD

 G

ROUND

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

=  C

ASE

 G

ROUND

Optional Shelf Harness and Light Circuits for 
 
Five Rows of Shelves

4 ft case

Connector

5

4

5

5

5

5

B

W

Connector

6 ft or 8 ft case

12 ft case

BL

BL

R

BL

R

BL

R

BL

W

R

W

R

B

R

BL

BL

R

4

B

BL

BL

BL

BL

BL

R

R

R

R

R

5

4

5

5

5

5

B

W

BL

BL

R

BL

R

BL

R

BL

W

R

W

R

B

R

BL

BL

R

4

B

BL

BL

BL

BL

BL

R

R

R

R

R

Optional Shelf Lighting

Fluorescent Fixtures

Содержание impact Excel C5NX-LE

Страница 1: ...ndard Fan Assembly 1 0392457 Fan Motor Evaporator MO 4410101 0382383 Fan Blade FB 4780617 4W Energy Efficient Fan Assembly 1 0477653 Fan Motor Evaporator MO 4410544 0382383 Fan Blade FB 4780617 Item P...

Страница 2: ...l legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70...

Страница 3: ...Indoor Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb C5NX LE 4 ft 1 6 6 ft 2 3 8 ft 3 2 12 ft 4 5 This is an average fo...

Страница 4: ...Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting T 8 Fluorescent 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Optional Lighting T 8 Fluoresce...

Страница 5: ...66 m3 m ARI Total Display Area 3 Sq Ft Ft 4 77 ft2 ft 1 45 m2 m Shelf Area 4 Sq Ft Ft 7 47 ft2 ft 2 28 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft...

Страница 6: ...Row Canopy Connector 5 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band Standard Lighting 1 Row Canopy Optional Lighting 2 Row Canopy 3 Row Canopy 5 4 5 5 Connector...

Страница 7: ...components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Five Rows of Shelves 4 ft...

Страница 8: ...R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNIN...

Отзывы: