REFRIGERATION DATA

Note: 

This data is based on store temperature and

humidity that does not exceed 75

°

F and 55% R.H. 

C5NX-LE

Deli

Dairy

Discharge Air °F

29

31

Evaporator °F

21

24

Unit Sizing °F

19

22

Btu/hr/ft — Unlit Shelves

C5NX-LE

‡‡

Parallel

Conventional

D

ELI

1715

1820

D

AIRY

1420

1555

‡‡ Add 10 Btu/hr/ft 

per shelf row

for LED fixtures.

Add 20 Btu/hr/ft 

per shelf row

for fluorescent lamps.

DEFROST DATA

C5NX-LE

Frequency Hrs

6

Defrost Water (lb/ft/day)

10.50

(± 15% based on case configuration and product

loading).

O

FFTIME

C5NX-LE

Temp Term °F

48

Failsafe Minutes

35

E

LECTRIC OR

G

AS

Not Recommended 

Standard Defrost Thermostat 

Close on rise: close 48°F  —  open 33°F 

CONVENTIONAL CONTROLS

Low Pressure Backup Control

CI/CO

*

C5NX-LE

Deli

Dairy

14°F / 4°F

17°F / 7°F

Indoor Unit Only, Pressure Defrost

Termination*

48°F

*Use a Temperature Pressure Chart to determine

PSIG conversions.

Estimated Charge (lb)**

C5NX-LE

4 ft

1.6

6 ft

2.3

8 ft

3.2

12 ft

4.5

**This is an average for all refrigerant types.

Actual refrigerant charge may vary by

approximately half a pound.

3 of 8

P/N 0480109_C

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

26 

3

/

(680)

25 

1

/

4   

(641)

37

 

(940)

28 

1

/

(724)

25 

1

/

4

 

(641)

61

 

(1549)

34 

5

/

8

 

(878)

FAN

L

17 

1

/

4

 

(438)

3 In. 

(77 mm) 

Required 

Air Gap

1

/

(183)

19 

5

/

8

 

(499)

5

/

8

 

(92)

21 

1

/

(540)

Refrigeration 

Outlet

7

/

8

 

(123)

54 

7

/

8

 

(1393)

3

/

(120)

Electrical 

Case to Case 

Connections

12 

1

/

4

 

(311)

81 

3

/

4

 

(2077)

Impact  

Excel

C5NX-LE

Dairy & Delicatessen

Dimensions shown as in. and (mm).

Multi-deck, 5 Display Levels, Low Front

C5NX-LE

NSF Certification

This merchandiser model is manufactured to meet ANSI/NSF
(National Sanitation Foundation) Standard #7 requirements for
construction, materials & cleanability.

Содержание impact Excel C5NX-LE

Страница 1: ...ndard Fan Assembly 1 0392457 Fan Motor Evaporator MO 4410101 0382383 Fan Blade FB 4780617 4W Energy Efficient Fan Assembly 1 0477653 Fan Motor Evaporator MO 4410544 0382383 Fan Blade FB 4780617 Item P...

Страница 2: ...l legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70...

Страница 3: ...Indoor Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb C5NX LE 4 ft 1 6 6 ft 2 3 8 ft 3 2 12 ft 4 5 This is an average fo...

Страница 4: ...Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting T 8 Fluorescent 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Optional Lighting T 8 Fluoresce...

Страница 5: ...66 m3 m ARI Total Display Area 3 Sq Ft Ft 4 77 ft2 ft 1 45 m2 m Shelf Area 4 Sq Ft Ft 7 47 ft2 ft 2 28 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft...

Страница 6: ...Row Canopy Connector 5 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band Standard Lighting 1 Row Canopy Optional Lighting 2 Row Canopy 3 Row Canopy 5 4 5 5 Connector...

Страница 7: ...components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Five Rows of Shelves 4 ft...

Страница 8: ...R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNIN...