![Hussmann HGL-1BS Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/hussmann/hgl-1bs/hgl-1bs_installation-and-service-instructions-manual_2189293017.webp)
TROUBLE SHOOTING CON’T
Compressor will not start,
cuts out on overload
1. Low voltage
1. Contact electrician
2. Defective compressor
2. Replace
3. Defective relay
3. Replace
4. Restriction or moisture
4. Leak check, replace
drier, evacuate and re-
charge
5. Inadequate air over con-
denser
5. Clean condenser
6. Defective condenser fan
motor
6. Replace
7. CRO not set properly
7. Reset to 10 psi.
Icing condition in drain pan 1. Low voltage
1. Check voltage at com-
pressor
2. Cabinet not level
2. Check front to rear level-
ing, adjust legs accordingly
3. Defective drain tube
heater
3. Replace
4. Defective drain pan
heater
4. Replace
LIGHTING SYSTEM
Lights won’t start
1. Check light switch
2. Check continuity to ballast
3. Check to see if bulbs are inserted properly into sock-
ets
4. Check voltage
Page 1
7