background image

CABINET  DIMENSIONS –

Cabinet

               Dimensions (inches)

Model                         Length

        Width

        Height    Ship

DCSG/DCCG      Outside        Inside            Outside *      Inside             Outside     Wt.

  -4                         25 3/8          21                  25 13/16       21 ½               51 ¼

  260

  -8

47 7/16

43 1/8

25 13/16

21 1/2

51 1/4

405

  -12

67 5/16

63

25 13/16

21 1/2

51 1/4

515

  -16

87 7/16

83 1/8

25 13/16

21 1/2

51 1/4

625

         *  -D models    (with doors) outside width  = 27 9/16

CABINET  CAPACITIES –

Cabinet
Model

  Cu.

  Capacity  (9 1/2 dia. 3 gal cans)

  # of lids

DCSG/DCCG        Ft.

     Upper Display      Lower Display

-4                          3.3                         4                          -                                  1
-8

8.9

8

4

1

-12

14.5

12

8

2

-16

20.2

16

12

2

       (Capacities of  D models are the same as models without doors)

ELECTRICAL  DATA

Cabinet

      Compressor

        Cabinet *

Model                        Volts        HP

   L.R.        F.L.            Nominal        Fuse

DCSG/DCCG

    Amps       Amps         Run Amps      Amps

  -4

  115

1/3

  33.0

6.4

 6.9

   15

  -8

115

1/2

58.0

8.6

9.5

15

  -12

115

1/2

45.0

7.8

9.9

15

  -16

115

3/4

59.8

10.2

10.5

15

        (electrical data of  D models are the same as standard models)
       * Includes main top heaters and

condenser

 fan motors

Due  to  compressor  change  from  semi-hermetic  to  hermetic  these  are  the  value  changes

  -8    (*hermetic)

115

   ½

 51.0

      .9

      8.4

    15

 -12   (*hermetic)

115

   ½

 87.0

     7.9

     12.0

    15

* effective Aug. 2002 the DCCG/DCSG-8 compressor changed from a semi-hermetic
HATB-005E-IAA  to  hermetic  T2155GK.

* effective Nov. 2003 the DCCG/DCSG-12 compressor changed from a semi-hermetic
KAGB-0050-IAA  to  hermetic  J2212GK  Aspera

4

Содержание DCCG-12

Страница 1: ...d DCSG D MODELS Dipping and Display Case P N OII DCCG DCSG January 2006 First Call for help US and Canada 1 800 922 1919 Soporte T cnico y Asistencia M xico 01 800 522 1900 For a Service Network Locat...

Страница 2: ...cation 5 Power Requirements 5 Start Up Procedures 5 Operation and Maintenance Temperature Control 6 Display Lighting 6 Anti sweat Heaters 6 Defrosting 6 Condensing Unit 7 Cleaning the Condenser 7 Clea...

Страница 3: ...TABLE OF CONTENTS CON T Dipping Using Guide Loading 10 Storage 10 Lids 10 Temperature Control 10 11 Load Limits 11 Dipping 11 Maintenance 11 Warranty and Parts Information 12 13 2...

Страница 4: ...tact the delivering carrier immediately and have his agent prepare an inspection report for the purpose of filing a claim This is your responsibility durability The entire assembly is then chemically...

Страница 5: ...e as models without doors ELECTRICAL DATA Cabinet Compressor Cabinet Model Volts HP L R F L Nominal Fuse DCSG DCCG Amps Amps Run Amps Amps 4 115 1 3 33 0 6 4 6 9 15 8 115 1 2 58 0 8 6 9 5 15 12 115 1...

Страница 6: ...same circuit Use a time delay fuse or circuit breaker The supply circuit must be properly grounded and conform to National and Local Electrical Codes Voltage as measured at the compressor terminals d...

Страница 7: ...d the heater fail it may be replaced by Raise top and canopy as an assembly and place wood spacers between top and cabinet Remove heater from under base frame Disconnect spade terminal splices and rem...

Страница 8: ...gas such as nitrogen Never use a wire brush to clean condenser tubes CLEANING EXTERIOR INTERIOR When cleaning the exterior of the cabinet use a soft cloth or sponge with water and mild detergent Rins...

Страница 9: ...Suction Pressure Head Pressure DCC SG 4 NE2134GK H 9 230 240 10 260 270 HATB 005E DCC SG 8 D CAA SH 6 230 240 7 245 255 DCC SG 8 D T2155GK H 9 230 240 10 235 245 DCC SG 12 D DCC SG 12 KAGB 005E IAA S...

Страница 10: ...ures 1 Temperature control not set properly 1 Reset control 2 Short of refrigerant 2 Leak check change drier evacuate and recharge 3 Cabinet location too warm 3 Relocate cabinet 4 Too much refrigerant...

Страница 11: ...res prior to placement in the display freezer Storage temperatures are generally maintained at 12 degrees F to 18 degrees F This allows for long term storage of ice cream without deterioration Dipping...

Страница 12: ...uccess of hand dipping and appeal of the stored ice cream to the customer depends on the training of personnel in proper dipping methods Periodic scraping of the container sidewalls and leveling off o...

Страница 13: ...ussmann Distributor for instructions on returning in warranty parts Warranty parts must be returned to the factory within 30 days of date of failure to assure proper disposition Lack of any of the abo...

Страница 14: ......

Страница 15: ......

Страница 16: ......

Страница 17: ......

Страница 18: ...FIED FRACTIONAL 1 32 DECIMAL 0 031 ANGULAR 1 HOLE LOCATION SPACING 1 64 22 26 24 28 30 6 23 27 25 29 31 5 C R S 1 2 S M START CAP RELAY OVERLOAD COMPRESSOR MOTOR COMPRESSOR TEMPERATURE CONTROL CONDENS...

Отзывы: