H1 Self Contained Multideck Case 

Installation Manual 

 

 
 

 

Reference: IM-1006 

 

The following models are covered by this Manual 

H1-10 & H1-14 

 
 
 

 

 
 
 
 

66 Glendenning Road, Glendenning NSW 2761 

PO Box 42 Doonside NSW 2767 

t: +61 2 8805 0400 

f: +61 2 9675 2897

 

Содержание Austral H1

Страница 1: ...ontained Multideck Case Installation Manual Reference IM 1006 The following models are covered by this Manual H1 10 H1 14 66 Glendenning Road Glendenning NSW 2761 PO Box 42 Doonside NSW 2767 t 61 2 88...

Страница 2: ...e installation 2 case services dimensions 2 Operating environment 5 Handling and transporting cases 5 Shipping damages and shortages 6 Installation 6 Positioning and levelling Commissioning 7 Cleaning...

Страница 3: ..._____________________________________________________________________________________ Hussmann Page 2 Pre installation Warning All refrigeration electrical and plumbing work must be carried out by lic...

Страница 4: ...Self Contained Multideck _________________________________________________________________________________________________________________________ Page 3 Hussmann H1 10 Foot Print H1 14 Foot Print fi...

Страница 5: ..._______________________________________________________________ Hussmann Page 4 Group Installations figure 2 acceptable group configurations NOTE Installing into an alcove is not recommended and will...

Страница 6: ...Cases must not be positioned in areas that may be subject to heat or air currents such as ventilation ducts open doors or windows direct sunlight electric fans or ovens etc Otherwise the cabinet may s...

Страница 7: ...trims etc are accounted for Immediately report any shipping damage to the carrier and inform Hussmann of any short supplies Installation NOTE Information in this manual is to be followed in conjuncti...

Страница 8: ...any racks and shelves etc that may have been removed during installation to store requirements NOTE Incorrect shelf configurations may compromise case performance Commissioning Cleaning case Remove th...

Страница 9: ...ioning Plan and risk assess the decommissioning process to include the following Isolate the case Removal of the case is to be in the reverse order of installation listed previously Disposal Case disp...

Страница 10: ...n the case as this may result in personal injury and or case damage 1 Remove stock from the case and store below 5 C 2 Turn off power to the case electrical 3 Remove all price tickets and any foreign...

Страница 11: ...1 Check that all case panels and trims are secure and undamaged 2 Check for rust and paint damage 3 Ensure all cable connections including screw terminals earth leads and straps are secure 4 Ensure in...

Страница 12: ...t remove the protection grill clean it very carefully avoid touching other components and put the grill back in its place 14 Clean the dissipater tray To reach the dissipater tray remove the protectio...

Страница 13: ...need more frequent defrost Case shelf arrangement has been deviated significantly from original specified setup Re do the shelf arrangement as per the original specification Air Return is blocked by...

Страница 14: ...ce provider Rust salt or other deposits bridging the sensor input signal The sensor tip s short circuited The compressor never stops The condenser is dirty Contact service provider The fluid is missin...

Страница 15: ...ched or crushed during the positioning of base trays shelves stock Staff must be trained in the correct procedures for setting up cases and ergonomic practices Slipping Drain may leak or become blocke...

Отзывы: