background image

iGiC-ism-0608

4

Bumper installation instructions

Step 1:  Make sure the aluminum channel and end caps   

 

are installed.

Step :  Use silicone lubricant to help the  

 

 

 

bumper slide into the channel.

Step 3:  Starting on one end: while inserting the bumper,   

 

push it up against the end cap to prevent  

 

 

the bumper from shrinking after installation  

 

 

(when it gets cold).

Step 4:  As you insert the bumper into the channel with    

 

one hand, pull the bumper toward you with  

 

 

the other to open the inside lips. Slowly   

 

 

apply pressure by rolling the bumper into  

 

 

the track.

1.   Check level of floor where cases are to be set. 

Determine the highest point of the floor; cases will 

be set off this point.

2.   Set first case, and adjust legs over the highest part of 

the floor so that case is level. Prevent damage - case 

must be raised under leg or by use of x6 or x4 leg 

brace. Remove side and back leg braces after case 

is set.

It is the contractor’s responsibility to install

case(s) according to local construction and

health codes.

installation (Cont'd)

Содержание Chino ISM

Страница 1: ...ISM CHeese deli island case P N IGic ism 0608 INSTALLATION OPERATION GUIDE CHINO ISM island cheese deli case Rev 0608 Installation Operation Manual...

Страница 2: ...ed Mini Island Display Shipping Damage All equipment should be thoroughly examined for shipping damage before and during unloading This equipment has been carefully inspected at our factory and the ca...

Страница 3: ...e to its permanent position as possible Remove the top of the crate Detach the walls from each other and remove from the skid Unbolt the case from the skid The fixture can now be lifted off the crate...

Страница 4: ...e hand pull the bumper toward you with the other to open the inside lips Slowly apply pressure by rolling the bumper into the track 1 Check level of floor where cases are to be set Determine the highe...

Страница 5: ...hat vinyl legs are positioned within the base grooves Roll vinyl top over full length of base then tap with rubber mallet to ensure vinyl is securely locked into the base 2b Rigid Top Snap the Rigid T...

Страница 6: ...yl top over full length of base then tap with rubber mallet to ensure vinyl is securely locked into the base 2b Rigid Top Snap the Rigid Top over the Rigid Base 3 If necessary wipe clean with any hous...

Страница 7: ...p so that vinyl legs are positioned within the base grooves Roll vinyl top over full length of base then tap with rubber mallet to ensure vinyl is securely locked into the base 2b Rigid Top Snap the R...

Страница 8: ...ype The standard refrigerant will be R 404A or R22 unless otherwise specified on the customer order Check the serial plate on the case for information Minimum opening for self contained condenser unit...

Страница 9: ...suction pressure with an accurate pressure gauge at the evaporator outlet 2 From a refrigerant pressure temperature chart determine the saturation temperature at the observed suction pressure 3 Measur...

Страница 10: ...suitable for large motors or other external appliances BEFORE SERVICING ALWAYS DISCONNECT ELECTRICAL POWER AT THE MAIN DISCONNECT WHEN SERVICING OR REPLACING ANY ELECTRICAL COMPONENT This includes but...

Страница 11: ...eria which will thrive in a deli department NOTE Soap and hot water are not enough to kill this bacteria A sanitizing solution must be included with each cleaning process to eliminate this bacteria SH...

Страница 12: ...Attachment Plugs to completely De energize unit Failure to disconnect both plugsmay result in damage to equipment serious personal injury This includes but not limited to Fans Heaters Thermostats and...

Страница 13: ...CORD EVAPORATOR FANS 2 00001212 12W 14A 120VAC EMB PAPST 9906 TERMINAL BLOCK 125 01 0295 BIRMINGHAM 860112 600W 5 0A 120 VAC 00007274 PRESSURE SAFETY POWER SWITCH 125 01 0271 L1 N G NEMA 5 15P POWER C...

Страница 14: ...PORATOR FANS 2 00001212 EMB PAPST 9906 M M TERMINAL BLOCK 125 01 0295 BRIMHAM 860112 600W 115 VAC 00007274 PRESSURE SAFETY DEFROST TIMER PARAGON ERC 2 120 240V 50 60 Hz 125 01 0722 POWER SWITCH 125 01...

Страница 15: ...ld perform a complete start up evaluation prior to the loading of food into the refrigerator which includes such items as a Initial temperature performance Coils should be properly fed with a refriger...

Страница 16: ...ith warm product 2 Is the product loaded beyond the Safe Load Line markers 3 Are the return air ducts blocked 4 Are the entering air ducts blocked 5 Is a dumped display causing turbulent air flow and...

Страница 17: ...rm up and prolonged temperature recovery Food store refrigerators are not food chillers nor can they reclaim quality lost through previous mishandling d Care must be taken when cross merchandising pro...

Страница 18: ..._________________________________ _______________ ___________________________________________________________________________________________________ _______________ __________________________________...

Отзывы: