8

Electrical

WIRING COLOR CODE

G R E E N

G RO U N D

P U R P L E

A N T I - S W E AT

O R A N G E

L I G H T S

Y E L L OW

R E C E P TA C L E

R E D   /   B L A C K  

T- S TAT   / S O L E N O I D 230V

BLACK / WHITE

T- S TAT   /   S O L E N O I D   115V

B ROW N

FAN MOTORS

CASE MUST BE GROUNDED

NOTE: Refer to label affixed to case to determine the actual

configuration as checked in the “TYPE INSTALLED” boxes.

ELECTRICAL CIRCUIT IDENTIFICATION

Standard lighting for all models will be full length fluores-
cent lamps located within the case at the top.
The switch controlling the lights, the plug provided for
digital scale, and the thermometer are located at the rear
of the case mullion.
The receptacle that is provided on the exterior back of
these models is intended for computerized scales with a
five amp maximum load, not for large motors or other
high wattage appliances. It should be wired to a dedicated
circuit.

ELECTRICAL SERVICE RECEPTACLES
(WHEN APPLICABLE)

The receptacles located on the exterior of the merchan-
diser are intended for scales and lighted displays. They
are not intended nor suitable for large motors or other
external appliances.

BEFORE SERVICING

ALWAYS DISCONNECT ELECTRICAL

POWER AT THE MAIN DISCONNECT

WHEN SERVICING OR REPLACING ANY

ELECTRICAL COMPONENT.

This includes (but not limited to) Fans, Heat-

ers, Thermostats, and Lights.

FIELD WIRING & SERIAL PLATE AMPERAGE

Field Wiring must be sized for component amperes
printed on the serial plate. Actual ampere draw may be
less than specified. Field wiring from the refrigeration

control panel to the merchandisers is required for re-
frigeration thermostats. Most component amperes are
listed in the “Case Specs” section, but always check the
serial plate.

BALLAST LOCATION

Ballasts are located within the access panel that runs
the length of the rear of the case. Refer to diagram on
page 6.

WIRING & SERIAL PLATE AMPERAGE

Field Wiring must be sized for component amperes
stamped on the serial plate.  Actual ampere draw may be
less than specified. Field wiring from the refrigeration con-
trol panel to the merchandisers is required for refrigera-
tion thermostats.  Most component amperes are listed in
the "Case Specs" section, but always check the serial plate.

ASHRAE COLOR CODE

NOTE: All other manufacturers; no known sensor codes

Case Control Systems

SENSOR

COLORS

Manufacturer ® >

EIL

CPC

Location

Coil Inlet

Color

Blue

Blue

Part#

225-01-1755225-01-3255

Coil Outlet

Color

Red

Red

Part#

225-01-1757225-01-3123

Discharge Air

Color

Green

Green

Part#

225-01-1756225-01-3260

Return Air

Color

Purple

Green

Part#

225-01-1758225-01-3260

Defrost Term.

Color

White

Orange

Part#

225-01-0650225-01-3254

Liquid Line

Color

White

Blue

Part#

225-01-0650225-01-3255

Содержание Chino DBP Series

Страница 1: ...Chino DBP DBRP 01 03 ISLAND PRODUCE REV 0210 Installation Operation Manual DBP DBRP 01 03 ISLAND PRODUCE P N IGIP DBP DBRP 01 03 0210 INSTALLATION OPERATION GUIDE...

Страница 2: ...ossible shortages of mate rial If a shortage should exist and is found to be the re sponsibility of Hussmann Chino notify Hussmann Chino If such a shortage involves the carrier notify the carrier imme...

Страница 3: ...n Ref 6 24 16 26 1 8 DBRP 03 Shown with Optional Ref High Center Divider and Refrigerated Lighted Shelves Scale 3 8 30 Optional Ref High Center Divider and Ref Lighted Shelves Optional Base Display C...

Страница 4: ...etach the walls from each other and remove from the skid Unbolt the case from the skid The fixture can now be lifted off the crate skid Lift only at base of stand EXTERIOR LOADING These models have no...

Страница 5: ...e and outside rear mullion on both cases to be joined 5 Apply liberal bead of case joint sealant butyl to dotted area shown in Fig 2 1 of first case Apply heavy amount to cover entire shaded area DO N...

Страница 6: ...e Store plumb ing system floor drains should be at least 14 off the center of the case to allow use of the P trap pipe section Never use two water seals in series in any one line Double P traps in ser...

Страница 7: ...section of this guide The number of defrosts per day should never change The duration of the defrost cycle may be adjusted to meet conditions present at your location ACCESS TO TX VALVES DRAIN LINES...

Страница 8: ...includes but not limited to Fans Heat ers Thermostats and Lights FIELD WIRING SERIAL PLATE AMPERAGE Field Wiring must be sized for component amperes printed on the serial plate Actual ampere draw may...

Страница 9: ...horten the shelf life of the product 8 Cold coils remove heat and moisture from the case and deposit this as frost onto the coil Thus a defrost is required The only other moisture within the case is t...

Страница 10: ...on loca tions Call for your closest location Ushio America Inc is located at 10550 Camden Drive Cypress CA 90630 T 5 BULBS Please note T 5 lights must be turned off and on after bulb replacement EVAPO...

Страница 11: ...1 32 2 4 30 Out 11 2 208 19 0 100 Air 4 3 50 In 230 14 750 18 41 36 50 to Opt Forced 8 x 10 50 min 1 65 3 0 30 Out 11 2 208 19 0 100 Air 5 3 50 In 230 16 750 18 41 36 50 to Opt Forced 8 x 10 50 min 1...

Страница 12: ...roller To Sensors S S MOTOR BALLAST B 232 B B MOTOR MOTOR MOTOR MOTOR MOTOR MOTOR MOTOR MOTOR MOTOR MOTOR MOTOR MOTOR 8 10 12 14 16 18 20 22 24 26 28 30 32 Evaporator Fan Motors Lighted Shelves Option...

Страница 13: ...l Only dbrp 01k dgn MOTOR MOTOR MOTOR S S To Sensors Case Controller Computer Red 115 230V Black White 115V T Stat Liquid Solenoid Optional Optional Electronic TXV Evaporator Fan Motors MOTOR MOTOR B...

Страница 14: ...Orange Field Connections between both sections S EEPR Valve Optional EEV TXV EEV TXV Optional 10 Case section 12 Case section Light switch in CAD Hussmann Corporation 13770 Ramona Avenue Chino Ca 917...

Страница 15: ...ould perform a complete start up evaluation prior to the loading of food into the refrigerator which includes such items as a Initial temperature performance Coils should be properly fed with a refrig...

Страница 16: ...ASHRAE Standard 72 and ASHRAE Standard 117 12 Are the shelf positions number and size other than recom mended by the manufacturer 13 Is there an improper application or control system 14 Is the evapor...

Страница 17: ...ing handled in processing When a cut or tray of meat is not to be worked on immediately the procedure should call for returning it to refrigeration h Keep tools clean and sanitized Since mechanical eq...

Страница 18: ...IGIP DBP DBRP 01 03 0210 18...

Страница 19: ...nder this warranty shall be limited to a period not to exceed five years from date of factory shipment On Hussmann refrigeration systems an additional 4 year extended warranty for the motor compressor...

Страница 20: ...r particular unit They can be found on a small metal plate on the unit Please note them below for future reference MODEL SERIAL NUMBER Chino Additional copies of thispublication may be obtained by con...

Отзывы: