THIS BOOKLET CONTAINS INFORMATION ON:

DBP, DBRP 01,03

Island Produce Cases

SHIPPING DAMAGE

All equipment should be thoroughly examined for ship-
ping damage before and during unloading.
This equipment has been carefully inspected at our fac-
tory and the carrier has assumed responsibility for safe
arrival. If damaged, either apparent or concealed, claim must
be made to the carrier.

APPARENT LOSS OR DAMAGE

If there is an obvious loss or damage, it must be noted on
the freight bill or express receipt and signed by the carrier’s
agent; otherwise, carrier may refuse claim. The carrier will
supply necessary claim forms.

CONCEALED LOSS OR DAMAGE

When loss or damage is not apparent until after equipment
is uncrated
, a claim for concealed damage is made. Make
request in writing to carrier for inspection within 15 days,
and retain all packaging. The carrier will supply inspection
report and required claim forms.

SHORTAGES

Check your shipment for any possible shortages of mate-
rial. If a shortage should exist and is found to be the re-
sponsibility of Hussmann Chino, notify Hussmann Chino. If
such a shortage involves the carrier, notify the carrier imme-
diately,
  and request an inspection. Hussmann Chino will
acknowledge shortages within ten days from receipt of
equipment.

HUSSMANN CHINO PRODUCT CONTROL

The serial number and shipping date of all equipment has
been recorded in Hussmann’s files for warranty and re-
placement part purposes. All correspondence pertaining
to warranty or parts ordering must include the serial num-
ber of each piece of equipment involved, in order to pro-
vide the customer with the correct parts.

The Hussmann warranty is printed on the back

of this guide.

General Instructions

Table Of Contents

General Instructions ................................................. 2
Cut & Plan Views ....................................................... 3
Installation ................................................................. 4

Leveling ................................................................................................................ 4
Splash Guard ....................................................................................................... 5

Plumbing .................................................................... 6

Waste Outlet And P-trap .................................................................................... 6

Refrigeration ............................................................. 7

T-stat Location ..................................................................................................... 7

Electrical .................................................................... 8

Wiring Color Code ............................................................................................... 8
Ashrae Color Code ............................................................................................... 8

User Information ...................................................... 9

Stocking ................................................................................................................ 9
Case Cleaning ....................................................................................................... 9

Maintenance .............................................................. 10

Electrical Precautions .......................................................................................... 10
Replacing Fluorescent Lamps .............................................................................. 10
Tips & Troubleshooting ....................................................................................... 10

Electrical And Refrigeration Specifications ............ 11
Electrical Schematics ............................................... 12
Appendices ................................................................ 13

Appendix A. – Temperature Guidelines .............................................................. 13
Appendix B. – Application Recommendations ................................................... 13
Appendix C. – Field Recommendations - .......................................................... 13
Appendix D. – Recommendations To User - ..................................................... 14

Содержание Chino DBP Series

Страница 1: ...Chino DBP DBRP 01 03 ISLAND PRODUCE REV 0210 Installation Operation Manual DBP DBRP 01 03 ISLAND PRODUCE P N IGIP DBP DBRP 01 03 0210 INSTALLATION OPERATION GUIDE...

Страница 2: ...ossible shortages of mate rial If a shortage should exist and is found to be the re sponsibility of Hussmann Chino notify Hussmann Chino If such a shortage involves the carrier notify the carrier imme...

Страница 3: ...n Ref 6 24 16 26 1 8 DBRP 03 Shown with Optional Ref High Center Divider and Refrigerated Lighted Shelves Scale 3 8 30 Optional Ref High Center Divider and Ref Lighted Shelves Optional Base Display C...

Страница 4: ...etach the walls from each other and remove from the skid Unbolt the case from the skid The fixture can now be lifted off the crate skid Lift only at base of stand EXTERIOR LOADING These models have no...

Страница 5: ...e and outside rear mullion on both cases to be joined 5 Apply liberal bead of case joint sealant butyl to dotted area shown in Fig 2 1 of first case Apply heavy amount to cover entire shaded area DO N...

Страница 6: ...e Store plumb ing system floor drains should be at least 14 off the center of the case to allow use of the P trap pipe section Never use two water seals in series in any one line Double P traps in ser...

Страница 7: ...section of this guide The number of defrosts per day should never change The duration of the defrost cycle may be adjusted to meet conditions present at your location ACCESS TO TX VALVES DRAIN LINES...

Страница 8: ...includes but not limited to Fans Heat ers Thermostats and Lights FIELD WIRING SERIAL PLATE AMPERAGE Field Wiring must be sized for component amperes printed on the serial plate Actual ampere draw may...

Страница 9: ...horten the shelf life of the product 8 Cold coils remove heat and moisture from the case and deposit this as frost onto the coil Thus a defrost is required The only other moisture within the case is t...

Страница 10: ...on loca tions Call for your closest location Ushio America Inc is located at 10550 Camden Drive Cypress CA 90630 T 5 BULBS Please note T 5 lights must be turned off and on after bulb replacement EVAPO...

Страница 11: ...1 32 2 4 30 Out 11 2 208 19 0 100 Air 4 3 50 In 230 14 750 18 41 36 50 to Opt Forced 8 x 10 50 min 1 65 3 0 30 Out 11 2 208 19 0 100 Air 5 3 50 In 230 16 750 18 41 36 50 to Opt Forced 8 x 10 50 min 1...

Страница 12: ...roller To Sensors S S MOTOR BALLAST B 232 B B MOTOR MOTOR MOTOR MOTOR MOTOR MOTOR MOTOR MOTOR MOTOR MOTOR MOTOR MOTOR 8 10 12 14 16 18 20 22 24 26 28 30 32 Evaporator Fan Motors Lighted Shelves Option...

Страница 13: ...l Only dbrp 01k dgn MOTOR MOTOR MOTOR S S To Sensors Case Controller Computer Red 115 230V Black White 115V T Stat Liquid Solenoid Optional Optional Electronic TXV Evaporator Fan Motors MOTOR MOTOR B...

Страница 14: ...Orange Field Connections between both sections S EEPR Valve Optional EEV TXV EEV TXV Optional 10 Case section 12 Case section Light switch in CAD Hussmann Corporation 13770 Ramona Avenue Chino Ca 917...

Страница 15: ...ould perform a complete start up evaluation prior to the loading of food into the refrigerator which includes such items as a Initial temperature performance Coils should be properly fed with a refrig...

Страница 16: ...ASHRAE Standard 72 and ASHRAE Standard 117 12 Are the shelf positions number and size other than recom mended by the manufacturer 13 Is there an improper application or control system 14 Is the evapor...

Страница 17: ...ing handled in processing When a cut or tray of meat is not to be worked on immediately the procedure should call for returning it to refrigeration h Keep tools clean and sanitized Since mechanical eq...

Страница 18: ...IGIP DBP DBRP 01 03 0210 18...

Страница 19: ...nder this warranty shall be limited to a period not to exceed five years from date of factory shipment On Hussmann refrigeration systems an additional 4 year extended warranty for the motor compressor...

Страница 20: ...r particular unit They can be found on a small metal plate on the unit Please note them below for future reference MODEL SERIAL NUMBER Chino Additional copies of thispublication may be obtained by con...

Отзывы: