Rev. 0308
17
Glass Adjustment and Replacement
Close-up of the clam-shell located on top
of the ASC case.
Close-up of the glass in the
upright position located on
top of the ASC case.
GLASS REPLACEMENT AND ADJUSTMENT
INSTRUCTIONS
In order to replace or adjust the glass, the glass must be
placed in the raised position. The underside of the
clamp is exposed, revealing the tightening screws. By
turning these screws counterclockwise 1/4 turn each,
the glass will be loosened for either removal or
adjustment. Note: Do not overtighten the screws since
damage may occur.
Back of
Case
Inside of
Case
PVC
U-Channel
1. Open
glass
panel. Relieve
the tension on
the hinge.
2. Loosen all the
set screws along
the bottom inside
edge of the glass
panel.
3. Remove
or
re-adjust the
glass panel.
servicing, always replace fan with a fan of the same specifi-
cations.
COPPER COILS
The copper coils used in Hussmann merchandisers may
be repaired in the field. Materials are available from
local refrigeration wholesalers.
Hussmann recommends using #15 Sil-Fos for repairs.
TIPS & TROUBLESHOOTING
Before calling for service, check the following:
1. Check electrical power supply to the equipment for
connection.
2. Check fixture loading. Overstocking case will affect
its proper operation.
3. If frost is collecting on fixture and/or product, check
that Humidity Control is working properly, and that
no outside doors or windows are open—allowing
moisture to enter
s
t
o
r
e
.
FOR PROMPT SERVICE
When Contacting the Factory
regarding problems, Be sure
to have the Case MODEL and
SERIAL NUMBER Handy.
This Information is on a plate
located on the case itself.