P/N 0399452_C

Merchandisers

®

Note: Changed items have been underlined.

Item Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES AND

T

HERMOSTATS

A.

9W

End Compartment Fan Assembly

(1)

0441749

Fan Motor, Standard (MO.4410575)

0377253

Fan Blade (FB.4780616)
embossing away from motor

B. 0398558

Standard Non-Adjustable (2)
Defrost Thermostat (CT.4481088)

Item Part #

Description

Wiring Item #

L

AMPS AND

B

ALLASTS

C. 0135966

Ballast, Electronic

(3)

1 lamp

(BA.4480883)

D. 0039764

Lamp Starter (EP.4481081)

(4)

E.

Fluorescent Lamp

(5)

Replace with like fixtures

CW2-EGE

Technical Data Sheet 

P/N  0399452_C

NSF

®

Certified

July  2007

©2007 HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM

We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.

Содержание IMPACT CW2-EGE

Страница 1: ...STS C 0135966 Ballast Electronic 3 1 lamp BA 4480883 D 0039764 Lamp Starter EP 4481081 4 E Fluorescent Lamp 5 Replace with like fixtures CW2 EGE Technical Data Sheet P N 0399452_C NSF Certified July 2007 2007 HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A U S CANADA 1 800 922 1919 MEXICO 1 800 522 1900 WWW HUSSMANN COM We reserve the right to change or revise specifications and product design ...

Страница 2: ...rical service to O S edge of front base rail 7 178 RH edge of case to center of knockout 46 7 8 1191 Length of electrical raceway 21 3 8 543 Waste Outlet Front RH edge of case to the center of waste outlet 11 7 8 301 Center of waste outlet to outside of front base rail 3 7 8 98 Water Seal Center of case to center of pipe connection 32 813 Outside diameter of the drip pipe 1 1 4 32 Water seal outle...

Страница 3: ...ne PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 4 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb CW2 EGE 1 7 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound Length Added to Lineup by Each End Partition in 1 1 2 3 of 6 P N 0399452_C 48 1219 Front of Case 16 in Shelf 12 in Shelf 10 3 4 273 5 127 32 813 6 3 8 16...

Страница 4: ...s 120V 60Hz 0 96 NA With Energy Efficient Fans 120V 60Hz See Note 1 below Maximum Over Current Protection 120V 20 Electric Defrost Heaters 208V NA NA Standard Lighting 1 Row Canopy 0 80 40 Optional Lighting 2 Rows Canopy See Note 2 below Optional Shelf Lighting 1 Row of Shelves 0 80 40 2 Rows of Shelves 1 60 80 Note 1 All CW2 end compartments are equipped with energy efficient fan motors as standa...

Страница 5: ... White 120V POWER 120V NEUTRAL Field GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost Case GROUND 2 Defrost Termination Thermostat Refrigeration Thermostat Dark Blue To Condensing Unit Light Blue 3 2 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND ...

Страница 6: ...RTMENT LIGHTING SCHEMATIC Standard canopy lighting and optional shelf lighting are shown 4 4 4 4 4 4 120V POWER 120V NEUTRAL WARNING All components must have mechanical ground and the merchandiser must be grounded Grayed components in 12 ft models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS ...

Отзывы: