background image

E

Optional 

Lights

A

D

E

H

B

G

C

F

P/N 0432520_B

Note: Changed items have been underlined.

Merchandisers

®

Item Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES

A. 0392457

Fan Motor, Evaporator 

(1)

115V, 4WSP, CW (MO.4410101)

Fan Blade, 6 Inch, 20°, CW
embossing toward motor, 

0425336

4 ft case (FB.0425336)

0420242

6 ft case (FB.4780638)

B. 0404551

Fan Motor, Ambient

(2)

115V, 15W, CW (MO.0404551)

Item Part #

Description

Wiring Item #

H

EATERS

C. Anti-Sweat Heater – Service Door Frame

(3)

0494978

4 ft case (HE.4850717)

0494979

6 ft case (HE.4850718)

D. Anti-Sweat Heater – Drain Line

(4)

0494988

4 ft case (HE.4850722)

0494988

6 ft case (HE.4850722)

E. Defrost Heater – Gravity Coil, 208V

(5)

0486058

4 ft case (HE.4850705)

0486059

6 ft case (HE.4850706)

F. Defrost Heater – Blower Coil, 208V

(6)

0486056

4 ft case (HE.4850703)

0486057

6 ft case (HE.4850704)

L

AMPS AND

B

ALLASTS

G. 0355716

Ballast, Electronic

2 lamps 

(BA.0355716)

(7)

H.

Fluorescent Lamp

(8)

Replace with like fixtures

SLGV

Technical Data Sheet 

P/N 0432520_B

NSF

®

Certified

July 2007

©2007 HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM

We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.

Содержание SLGV

Страница 1: ... 6 ft case HE 4850722 E Defrost Heater Gravity Coil 208V 5 0486058 4 ft case HE 4850705 0486059 6 ft case HE 4850706 F Defrost Heater Blower Coil 208V 6 0486056 4 ft case HE 4850703 0486057 6 ft case HE 4850704 LAMPS AND BALLASTS G 0355716 Ballast Electronic 2 lamps BA 0355716 7 H Fluorescent Lamp 8 Replace with like fixtures SLGV Technical Data Sheet P N 0432520_B NSF Certified July 2007 2007 HUS...

Страница 2: ... mm to the length of the lineup Electrical Service B RH end of case to Electrical raceway right edge 7 178 7 178 C RH end of case to Electrical raceway left edge 41 3 8 1051 32 3 4 831 Back of case to center of knockout 3 5 8 92 3 5 8 92 Electrical Field Wiring Connection Point Waste Outlet D RH end of case to the center of waste outlet 24 610 24 610 Back of case to center of waste outlet 25 5 8 6...

Страница 3: ...tion and product loading ELECTRIC SLGV Temp Term F NA Failsafe minutes 30 OFFTIME OR GAS Not Recommended Standard Defrost Thermostat NA CONVENTIONALCONTROLS Low Pressure Backup Control SLGV CI CO 27 F 37 F Indoor Unit Only Pressure Defrost Termination Temp F Not Recommended Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser SLGV Drip Pipe in 1 1 2 Liquid Line...

Страница 4: ...0 52 1 04 1 04 1 56 30 60 60 90 Energy Efficient NA NA NA NA NA NA NA NA Export 230V 50 hz NA NA 0 36 0 54 NA NA 60 90 Anti sweat Heaters on Fan Circuit 1 28 1 92 NA NA 154 230 NA NA Constant On Anti sweat Heaters NA NA NA NA NA NA NA NA Cycling Anti sweat Heaters NA NA NA NA NA NA NA NA Minimum Circuit Ampacity With Standard Fans 60 hz 2 31 3 95 1 82 2 63 With Energy Efficient Fans NA NA NA NA Wi...

Страница 5: ...R Red G Green BL Blue LB Light Blue DB Dark Blue B Black W White 120V POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers Grayed components in 12 foot models only Evaporator Fan and Anti Sweat Heaters Electric Defrost Heaters Ambient Air Wipe Fans L1 208V POWER FROM DEFROST CONT...

Страница 6: ... POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers Grayed components in 12 foot models only 120V NEUTRAL ORANGE OR TAN BAND 120V POWER ORANGE OR TAN BAND B BL 7 8 R G 8 7 R BL G W B Optional Lighting Ledge Light Standard Lighting LIGHT SWITCH ...

Отзывы: