![Husqvarna TS 355 B Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/husqvarna/ts-355-b/ts-355-b_operators-manual_172946016.webp)
OPERATION
WARNING!
Always make sure the saw is connected to a properly
grounded electrical outlet. Failure to comply with this
warning could result in serious bodily injury or death!
Check Before Operation:
•
Make sure that extension cord length is properly sized
for motor used on saw. See chart below.
Electric Motor Plugs & Connectors
Motor
Wired For
Voltage
Motor Pigtail
Plug
(NEMA No.)
Connector
Required
(NEMA No.)
1-1/2 HP
115 V
L5-20P
L5-20R
2 HP
230 V
L6-15P
L6-15R
3 HP
230 V
L6-30P
L6-30R
NOTICE
DO NOT operate on low voltage! Low voltage causes
loss of power, motor overheating, and possibly motor
winding burnout. Voltage should be checked at the mo-
tor while it is operating.
EXTENSION CORD SIZE (A.W.G. Minimum)
Motor
HP
25 ft
50 ft
120 V
120 V
AWG
14
12
100 ft
120 V
Not recommended
150 ft
120 V
•
In case of a malfunction, grounding provides a path of
least resistance for electric current to reduce the risk of
electric shock.
Do not modify the plug provided. If it will not fit, have
the proper outlet installed by a qualified electrician. If
repair or replacement of the electric plug is necessary,
do not connect the equipment-grounding conductor to a
live terminal.
•
Surface
Power
Tool
Drip Loop
Power
Cord
Supporting
(A)
(B)
(C)
(D)
ADAPTER
Grounding
Pin
Grounding
Means
Grounding
Pin
Cover of Grounded
Outlet Box
Metal Screw
Use only extensions cords that are intended for
outdoor use and have an electrical rating not less than
the rating of the product. Use only 3-wire extension
cords that have 3-prong grounding plugs and 3-pole
receptacles that accept the tool's plug.
Keep all connections dry, off the ground, away from-
heat and sharp edges. Always disconnect the exten-
sioncord from the receptacle before disconnecting the
product form the extension cord. Do not touch the plug
with wet hands. Repair or replace a damaged or worn
cord immediately.
To avoid getting the plug wet, a "drip loop” should be
arranged to properly position the power cord relative to
the power source, as indicated above. The "drip loop"
is that part of the cord below the level of the receptacle,
or the connector, if an extension cord is used. This
method of positioning the cord prevents water from
travelling along the power cord and coming in contact
with the receptacle.
If the plug or receptacle gets wet, DO NOT unplug the
cord. Disconnect the fuse or circuit breaker that
supplies power to the tool. Then unplug and examine
for presence of water in the receptacle.
This saw is intended for use on a circuit as shown
above. The tool has a grounding plug (A). A temporary
adapters (C) may be used to connect this plug to a
2-pole receptacle (B), if a properly grounded outlet is
not available. The adapter should be used only until a
grounded outlet can be installed by a qualified electri-
cian.
NOTE: Use of a temporary adapter is not permitted in
Canada.
•
•
•
•
•
15