18 SERVICE WORK ON THE ENGINE
131
Danger
Danger of poisoning
Exhaust gases are toxic and
inhaling them may result in unconsciousness and
death.
–
Always make sure there is sufficient ventilation
when running the engine.
–
Use an effective exhaust extraction system when
starting or running the engine in an enclosed
space.
–
Start the engine and check the response.
18.2
Checking 2-stroke oil level
Warning
Engine failure
The engine will not be lubricated unless there is 2-stroke oil in the oil tank.
If the oil level warning light lights up, the 2-stroke oil is sufficient for the remaining tank of fuel.
–
As soon as the oil level warning light lights up, ride for no longer than until the remaining fuel in the
tank is depleted.
–
At the next opportunity add 2-stroke oil before you refuel.
–
Time the oil pump if the 2-stroke oil hose has been removed or the 2-stroke oil tank has been fully
depleted in error.
Preparatory work
–
Stand the motorcycle upright on a horizontal surface.
V00925-10
Main work
–
Check the 2-stroke oil level in the oil tank.
Info
For one tank of fuel, the 2-stroke oil tank must be filled
up to at least the
MIN
marking
A
.
The 2-stroke oil tank must be completely if possible.
» If the 2-stroke oil level is too low:
–
Add 2-stroke oil. (
Содержание TE 250i
Страница 1: ...OWNER S MANUAL 2018 TE 250i TE 300i Art no 3402171en ...
Страница 2: ......
Страница 57: ...11 TUNING THE CHASSIS 55 Info Make sure the gap widths are even ...
Страница 125: ...16 COOLING SYSTEM 123 Finishing work Check the coolant level p 120 ...