6
FORK, TRIPLE CLAMP
201730-10
•
I
201788-10
-
Remove the compression shim stack
0.
-
Remove spring.
-
Remove adapter
(D
with spring @ and washer .
-
Remove spring
@).
-
Remove valve needle
@)
from the piston rod.
Info
The adjusting tube can be used for this.
Disassembling the hydrostop unit
Info
The steps are identical for both fork legs.
Preparatory work
-
Disassemble the fork legs. (
a
p. 17)
Main work
-
Mount the hydrostop unit on a fitting hexagon socket and clamp into a vice.
-
Remove sleeve
O.
-
Remove shim stack
8.
-
Remove adapter (D.
-
Remove hub
C,
with washers
C,.
•
Info
I
It is possible that only one washer or no washer is present.
-
Remove the O-ring from the hub.
22